beautypg.com

BatteryMINDer 24041-AA-S1 User Manual

Page 30

background image

Rev. F-103007

P/N VDC24041AA-S1-MNL

BatteryMINDer

®

Model 24041-AA-S1

Page 30

DETAILED SPECIFICATIONS - VDC Model No. 24041-AA-S1 (con’t.)

Charging Output Control Characteristics

Charging Flow : Battery condition detect>Soft Start Charge>Bulk Charge>Absorption

Charge>Sulfate Check>Float Charge

Soft Start Charging Activity conditions: Battery Voltage is over 6 Vdc and less than 21Vdc

Soft Start Charging output current control: (4A mode) 4 ±0.25 Adc

Soft Start Charging Time Limited: (Stop charge If battery cannot be charged over 10.5V after

6 hrs, Error LED flash indicated) 6 ±0.25 Hours

Bulk Charging Activity conditions: Battery Voltage is over 21Vdc

Bulk Charging Current control at 4A mode: (Selected by pressing “Until 4A Lit” Button)

4 +0.22 / -0 Adc

Max. rated output voltage and current: 26.0V at 4Adc 27.2V at 3.25Adc

Bulk Charging Time Limited: (Stops charge If battery cannot be charged reach 28.2

after 20 hrs, error LED flash indicated) 20 ±1 Hours