BatteryMINDer 24041-AA-S1 User Manual
Page 30
Rev. F-103007
P/N VDC24041AA-S1-MNL
BatteryMINDer
®
Model 24041-AA-S1
Page 30
DETAILED SPECIFICATIONS - VDC Model No. 24041-AA-S1 (con’t.)
•
Charging Output Control Characteristics
•
Charging Flow : Battery condition detect>Soft Start Charge>Bulk Charge>Absorption
Charge>Sulfate Check>Float Charge
•
Soft Start Charging Activity conditions: Battery Voltage is over 6 Vdc and less than 21Vdc
•
Soft Start Charging output current control: (4A mode) 4 ±0.25 Adc
•
Soft Start Charging Time Limited: (Stop charge If battery cannot be charged over 10.5V after
6 hrs, Error LED flash indicated) 6 ±0.25 Hours
•
Bulk Charging Activity conditions: Battery Voltage is over 21Vdc
•
Bulk Charging Current control at 4A mode: (Selected by pressing “Until 4A Lit” Button)
4 +0.22 / -0 Adc
•
Max. rated output voltage and current: 26.0V at 4Adc 27.2V at 3.25Adc
•
Bulk Charging Time Limited: (Stops charge If battery cannot be charged reach 28.2
after 20 hrs, error LED flash indicated) 20 ±1 Hours