BatteryMINDer 24041-AA-S1 User Manual
Page 31
Rev. F-103007
P/N VDC24041AA-S1-MNL
BatteryMINDer
®
Model 24041-AA-S1
Page 31
DETAILED SPECIFICATIONS - VDC Model No. 24041-AA-S1 (con’t.)
Absorption mode transitions to Float mode conditions in AGM setting:
Mode: 1) Charging current
2) 5 Hours Time-out: after 5 Hours unit switches to Float Charge Mode
Absorption mode Thermal Runaway Protection: Stops Charging when the second current sample is
larger the first current sample (Positive dI/dt)
Switch to Float mode in Bulk charge or Absorption mode when Battery type Button is Pressed For
3 Seconds or longer.
GREEN
Charge - Float LED will blink
Float Charge output Voltage control
26.1 ±0.25 Vdc
Float Charge current control
(4A Rate) 2 Adc±0.25
Float charge transitions to PWM Float Charge Mode after 1 Hour
Float Pulse Charge voltage control 26.1@24°V ±0.25 Vdc
Float Pulse Charge current control: (4A Rate) 2 Adc ±0.25