BatteryMINDer 24041-AA-S1 User Manual
Page 11
Rev. F-103007
P/N VDC24041AA-S1-MNL
BatteryMINDer
®
Model 24041-AA-S1
Page 11
Failure to test a “rested” (see pg. 9) battery will
cause false readings. Be certain to read and
understand all safety related instructions (pages 3
to 7) before proceeding further.
2.
Measure battery’s voltage, without any load
attached. If the voltage is less than 24.8 volts
(Typically 50% of charge) the battery may be too
heavily sulfated to be fully recoverable. If voltage
is 24.8-V or higher full recovery can be expected,
given sufficient time (average 1-2 weeks for batter-
ies that are heavily sulfated).
3.
Connect the BatteryMINDer to the battery.
Select type of battery.
4.
Charge battery to its maximum level. Press
Maintenance-Float (select Battery type) button, if
it does not go into this mode automatically. Allow
battery to remain for a minimum of 72 hours
before retesting. If improvement is seen, continue
until battery voltage reaches full capacity level or
no further increase is seen.
Note: Do not expect to completely eliminate
sulfate in a few days. Long established sul-
fate will require several weeks or longer to
be fully dissolved. Be patient and you will be
rewarded with a “sulfate-free” battery.
OCV - “Rested”
Voltage
Full Capacity
Percentage
25.8 - 26.2 Volts
100%
25.2 - 25.8 Volts
75%
24.8 - 25.2 Volts
50%
24.4 - 24.8 Volts
25%
24.0 - 24.4 Volts
0%
<22 Volts
= shorted
OCV=Open Circuit No Load Voltage
TABLE 2