Specifications

VITS 100 NTSC VITS Inserter Instruction Manual

3–3

Table 3–4: FCC Composite characteristics

Characteristic

Information

Timing

See Figure 3–5

Modulated 5-step Staircase

Luminance

Amplitude

80.4 IRE

±

0.7 IRE

Riser Amplitude

1/5 of 5-step amplitude

±

0.5%

Rise Time

250 ns

±

25 ns

Chrominance

Phase

Same as burst

±

0.3

°

Envelope Risetime

375 ns

±

37.5 ns

2T Pulse

Pulse-to-Bar Ratio

100%

±

0.5%

Half Amplitude Duration (HAD)

250 ns

±

25 ns

Ringing

1.0 IRE or less

Modulated SIN

2

Pulse

Pulse-to-Bar Peak Amplitude

100%

Half Amplitude Duration

1.563

ms

±

150 ns

Phase

60.8

°

±

1

°

Bar

Amplitude

100 IRE

±

1 IRE

Rise Time

250 ns

±

25 ns