Specifications

VITS 100 NTSC VITS Inserter Instruction Manual

3–11

Table 3–19: Certifications and compliances

Category

Standards or description

EC Declaration of Conformity –
EMC

Meets intent of Directive 89/336/EEC for Electromagnetic Compatibility. Compliance was
demonstrated to the following specifications as listed in the Official Journal of the European Union:

EN 50081-1 Emissions:

EN 55022

Class B Radiated and Conducted Emissions

EN 50082-1 Immunity:

IEC 801-2

Electrostatic Discharge Immunity

IEC 801-3

RF Electromagnetic Field Immunity

IEC 801-4

Electrical Fast Transient/Burst Immunity

Australia/New Zealand
Declaration of Conformity – EMC

Complies with EMC provision of Radiocommunications Act per the following standard(s):

AS/NZS 2064.1/2

Industrial, Scientific, and Medical Equipment: 1992

AS/NZS 3548

Information Technology Equipment: 1995

EMC Compliance

Meets the intent of Directive 89/336/EEC for Electromagnetic Compatibility when it is used with the
product(s) stated in the specifications table. Refer to the EMC specification published for the stated
products. May not meet the intent of the directive if used with other products.

FCC Compliance

Emissions comply with FCC Code of Federal Regulations 47, Part 15, Subpart B, Class A Limits.

Installation (Overvoltage)
Category

Terminals on this product may have different installation (overvoltage) category designations. The
installation categories are:

CAT III

Distribution-level mains (usually permanently connected). Equipment at this level is
typically in a fixed industrial location.

CAT II

Local-level mains (wall sockets). Equipment at this level includes appliances, portable
tools, and similar products. Equipment is usually cord-connected.

CAT I

Secondary (signal level) or battery operated circuits of electronic equipment.

Pollution Degree

A measure of the contaminates that could occur in the environment around and within a product.
Typically the internal environment inside a product is considered to be the same as the external.
Products should be used only in the environment for which they are rated.

Pollution Degree 2

Normally only dry, nonconductive pollution occurs. Occasionally a
temporary conductivity that is caused by condensation must be
expected. This location is a typical office/home environment.
Temporary condensation occurs only when the product is out of
service.

Safety Standards

U.S. Nationally Recognized
Testing Laboratory Listing

UL1244

Standard for electrical and electronic measuring and test equipment.

Canadian Certification

CAN/CSA C22.2 No. 231

CSA safety requirements for electrical and electronic measuring and
test equipment.

European Union Compliance

Low Voltage Directive 73/23/EEC, amended by 93/69/EEC

EN 61010-1

Safety requirements for electrical equipment for measurement,
control, and laboratory use.