Specifications

3–10

VITS 100 NTSC VITS Inserter Instruction Manual

Table 3–18: Environmental characteristics

Characteristic

Information

Temperature

Non-Operating

–40

°

to +65

°

C (–40

°

to +149

°

F)

Operating

0

°

to +50

°

C (32

°

to 122

°

F)

Altitude

Non-Operating

To 50,000 ft (15,240 m)

Operating

To 15,000 ft (4,572 m)

Vibration (Operating)

Fifteen minutes each axis at 0.025 inch, frequency varied from 10-55-10 Hz in 4-minute
cycles with the instrument secured to the vibration platform; ten minutes each axis at any
resonant point, or at 55 Hz.

Shock

50 G,

1

/

2

sine, 11 ms duration, three guillotine shocks per side

Transportation

Qualified under NTSB Test Procedure 1A, Category II (36-inch drop)