T-2500se specifications – Atec Thermonics-T-2500SE User Manual
Page 6
T-2500SE SPECIFICATIONS
*Specifications subject to change without notice.
' 4/2005 Thermonics Inc.
Printed in U.S.A.
1288 Reamwood Ave.
Sunnyvale, California 94089-2233
Phone: (408) 542-5900
Fax: (408) 542-5910
E-Mail: [email protected]
URL: http://www.thermonics.com
GENERAL DESCRIPTION
Method of Cooling: Forced air with single-stage mechanical
refrigeration and multi-stage self-cooling heat exchanger. Non-CFC
based refrigerants are used - environmentally safe.
Method of Heating: Forced air with in-line air heaters.
Operator Interface: Color LCD display, menu-driven touch-screen
with software menu selections. Software contains system self
diagnostics. Uses graphical software to select system menus such as
operating mode, and to set system parameters such as temperature
setpoint or flow rate.
Data Communications: Interfaces to ATE systems. Contains IEEE-
488.2, RS-232C, Standard Tester Interface, and Printer ports. Software
communication parameters are configurable to accommodate varying
systems.
TEMPERATURE PERFORMANCE
Range
Accuracy
Stability
Displayed
Transition
††
(
°C)
(
°C)
(
°C)
Resolution
Time
(
°C)
(sec)
T-2500E
-80
–
225
±
1.0
±
0.3
0.1
10
T-2500SE
-90
–
225
±
1.0
±
0.3
0.1
4
T-2500BE
-80
–
225
±
1.0
±
0.3
0.1
120
T-2500IX
-100
–
225
±
1.0
±
0.3
0.1
4
T-2500IX/M
-130
–
225
±
1.0
±
0.3
0.1
10
AIR FLOW
200 to 900 SCFH (1.6 to 7.6 liters/sec.). Flow is under software
control.
ENVIRONMENTAL REQUIREMENTS
Ambient Temperature Range: 15
°C to 28°C
Relative Humidity: 20 - 65%
AIR INPUT REQUIREMENTS
Pressure: 80-110 PSIG (5.7 - 7.8 Kg/Cm
2
)
Flow Rate: 18 SCFM (8.6 liters/sec)
Dew Point: Less than 10C at 80 PSIG (5.7 Kg/Cm
2
)
Quality: Clean air; free of oil, moisture and particles
PHYSICAL CHARACTERISTICS
Height
Width
Depth
Weight
(in/cm)
(in/cm)
(in/cm)
(lbs/kgm)
55/139
25/63
28/71
350/160
POWER REQUIREMENTS
Volts
Hertz
Phases
Amps
208
–
230
50/60
1
ø
20
SYSTEM FEATURES
Temperature sensor: Device Under Test (DUT), K-type and T-Type
thermocouples. Also, K-type thermocouple for air temperature.
Controller: An 80X86, MS-DOS based microcomputer.
Fail safes: Snap-disc thermostats, air flow sensors and
thermocouples. Over-temperature limit of 245C.
Min
Max
(in/cm)
(in/cm)
X 27/69
44/112
R 34/86
48/122
FEATURES
·
Fast temperature response time
·
Temperature range of -90C to +225C
·
Environmentally safe
·
Fully grounded
·
Small footprint
·
Fast DUT temperature stabilization time
·
Color LCD display with touch-screen, operator interface
·
Flexible ATE communications
·
Sophisticated system self diagnostics
·
±
±
1C accuracy with 0.1C readout
·
Motorized support arm
·
High air flow rate
·
Frost free operation
·
Graphical display of temperature response
The model T-2500SE PTFS is designed to comply with the following
specifications. The system has been factory tested to verify conformance.*
Maximum cold specifications are for room ambient temperature of 77
°F (25°C), or lower, using 60Hz
power. Cold temperature specifications are degraded 5
°C for 50Hz operation.
††
Transition time is
between +125
°C and -55°C; air temperature measured at air output nozzle. Measured in temperature
cycle mode after system stabilization with a 10-second soak time, or less, at each temperature.
A Test Enterpises Company