beautypg.com

Model dchv-1, Model dcv-1, Model d591 – Atec Thermo-ECAT-LTS User Manual

Page 6

background image

Accessories

T

her

m

o
Sc
ient

if

ic

EC
AT

Li

ght

ni

n

g
T

es
t

Sy
s

tem
(

LT
S)

Model DCI-1

Cable Induction Coupler for WF1, 4, 5A, 5B

General Specifications
WF1

6.4/69 µs, >2000 Vlimit, >5000 Atest

WF4

See Technical Note #201

WF5A

40/120 µs, >1200 Vlimit, >10,000 Atest

WF5B

50/500 µs, >900 Vlimit, >6000 Atest

Safety Features

Double Insulated
Safety Sockets

Physical Specifications
Height

21.6 cm (8.5 in)

Width

28.3 cm (11.1 in)

Depth

34.3 cm (13.5 in)

Aperture

3.8 cm x 7.6 cm(1.5 in x 3 in)

Weight

48 kg (106 lb)

CE Marking

Safety and EMC Directives

Model DCHV-1

Cable Induction Coupler for WF3, 6

General Specifications
WF3/1 MHz

1 MHz, >4000 Vtest, >300 Alimit

WF3/10 MHz

10 MHz, >4000 Vtest, >20 Alimit

WF6

0.2/4µs, >4000 Vlimit, >160 Atest

Safety Features

Double Insulated
Safety Sockets

Physical Specifications
Height

14.2 cm (5.6 in)

Width

12.7 cm (5.0in)

Depth

31.8 cm (12.5 in)

Aperture

3.8 cm x 5.1 cm (1.5 in x 2 in)

Weight

13 kg (29 lb)

CE Marking

Safety and EMC Directives

Model DCV-1

Cable Induction Coupler for WF2 (use 2 for Level 5)

General Specifications
WF2

0.1/6.4 µs, >2000 Vtest, >1700 Alimit

Safety Features

Double Insulated
Safety Sockets

Physical Specifications
Height

14.2 cm (5.6 in)

Width

12.7 cm (5.0in)

Depth

31.8 cm (12.5 in)

Aperture

3.8 cm x 5.1 cm (1.5 in x 2 in)

Weight

13 kg (29 lb)

CE Marking

Safety and EMC Directives

Model D591

Powered Pin Decoupler Module for Powered Pin Injection

General Specifications
Operating AC Voltage

0-244 VAC, 20 A

Operating DC Voltage

0-285DC, 10 A

Operating Frequency

0-400 Hz

Safety Features

Safety Sockets

Physical Specifications

Half-width ECAT plug-in module

CE Marking

Safety and EMC Directives