Model dchv-1, Model dcv-1, Model d591 – Atec Thermo-ECAT-LTS User Manual
Page 6
Accessories
T
her
m
o
Sc
ient
if
ic
EC
AT
Li
ght
ni
n
g
T
es
t
Sy
s
tem
(
LT
S)
Model DCI-1
Cable Induction Coupler for WF1, 4, 5A, 5B
General Specifications
WF1
6.4/69 µs, >2000 Vlimit, >5000 Atest
WF4
See Technical Note #201
WF5A
40/120 µs, >1200 Vlimit, >10,000 Atest
WF5B
50/500 µs, >900 Vlimit, >6000 Atest
Safety Features
Double Insulated
Safety Sockets
Physical Specifications
Height
21.6 cm (8.5 in)
Width
28.3 cm (11.1 in)
Depth
34.3 cm (13.5 in)
Aperture
3.8 cm x 7.6 cm(1.5 in x 3 in)
Weight
48 kg (106 lb)
CE Marking
Safety and EMC Directives
Model DCHV-1
Cable Induction Coupler for WF3, 6
General Specifications
WF3/1 MHz
1 MHz, >4000 Vtest, >300 Alimit
WF3/10 MHz
10 MHz, >4000 Vtest, >20 Alimit
WF6
0.2/4µs, >4000 Vlimit, >160 Atest
Safety Features
Double Insulated
Safety Sockets
Physical Specifications
Height
14.2 cm (5.6 in)
Width
12.7 cm (5.0in)
Depth
31.8 cm (12.5 in)
Aperture
3.8 cm x 5.1 cm (1.5 in x 2 in)
Weight
13 kg (29 lb)
CE Marking
Safety and EMC Directives
Model DCV-1
Cable Induction Coupler for WF2 (use 2 for Level 5)
General Specifications
WF2
0.1/6.4 µs, >2000 Vtest, >1700 Alimit
Safety Features
Double Insulated
Safety Sockets
Physical Specifications
Height
14.2 cm (5.6 in)
Width
12.7 cm (5.0in)
Depth
31.8 cm (12.5 in)
Aperture
3.8 cm x 5.1 cm (1.5 in x 2 in)
Weight
13 kg (29 lb)
CE Marking
Safety and EMC Directives
Model D591
Powered Pin Decoupler Module for Powered Pin Injection
General Specifications
Operating AC Voltage
0-244 VAC, 20 A
Operating DC Voltage
0-285DC, 10 A
Operating Frequency
0-400 Hz
Safety Features
Safety Sockets
Physical Specifications
Half-width ECAT plug-in module
CE Marking