Model d562-lx, Model d563-lx, Model d564-lx – Atec Thermo-ECAT-LTS User Manual
Page 5: Model d569-lx, Model d568-l5

T
her
m
o
Sc
ient
if
ic
EC
AT
Li
ght
ni
n
g
T
es
t
Sy
s
tem
(
LT
S)
Model D562-Lx
LTS Module for WF2 (x indicates level 3, 4 or 5)
For Cable Induction use Model DCV-1 Cable Induction
Coupler (use 2 for Level 5)
General Specifications
WF2 (CI,GI)
Single Stroke , 0.1/6.4 µs, 25-1920 V, 1700 Asc
Multiple Strokes, 0.1/6.4 µs, 25-1200 V
WF2 Pin Injection Coming soon on new module
Safety Features
Door Interlocks
Safety Sockets
Outputs only connected during Transient
Active Module indicator LED
Voltage Present indicator LED
Environmental Operating Conditions
Operating temperature
+15°C to +35°C
Humidity
10-75%, non-condensing
Physical Specifications
Half-width ECAT plug-in module
CE Marking
Safety and EMC Directives
Model D563-Lx
LTS Module for WF3-1 MHz and 10 MHz (x indicates level 3, 4
or 5)
For Cable Induction use Model DCHV-1 Cable Induction
Coupler
General Specifications
WF3 (CI,GI)
Single Stroke , 1 MHz, 25-4000 V, 160 Asc
Multiple Strokes, 1 MHz, 25-2400 V
Multiple Burst, 1 MHz, 25-2300V
Single Stroke , 10 MHz, 25-4000 V, 60 Asc
Multiple Strokes, 10 MHz, 25-2400 V
Multiple Burst,10 MHz, 25-2300V
WF3 Pin Injection 1 MHz, 30-4000 Voc/1.2-160 Asc = 25 Ohm
Safety Features
Door Interlocks
Safety Sockets
Outputs only connected during Transient
Active Module indicator LED
Voltage Present indicator LED
Environmental Operating Conditions
Operating temperature
+15°C to +35°C
Humidity
10-75%, non-condensing
Physical Specifications
Full-width ECAT plug-in module
CE Marking
Safety and EMC Directives
Model D564-Lx
LTS Module for WF5B (x indicates level 3, 4 or 5)
For Cable Induction use Model DCI-1 Cable Induction Coupler
General Specifications
WF5B (CI,GI)
Single Stroke , 50/500 µs, 150-6000 A, 900 Voc
Multiple Strokes, 50/500 µs, 30-1500 V
WF5B Pin Injection 50/500 µs,50-1800 Voc/50-1800 Asc = 1 Ohm
Safety Features
Door Interlocks
Safety Sockets
Outputs only connected during Transient
Active Module indicator LED
Voltage Present indicator LED
Environmental Operating Conditions
Operating temperature
+15°C to +35°C
Humidity
10-75%, non-condensing
Physical Specifications Full-width ECAT plug-in module
CE Marking Safety and EMC Directives
Model D569-Lx
LTS Module for WF6 (x indicates level 3, 4 or 5)
For Cable Induction use Model DCHV-1 Cable Induction
Coupler
General Specifications
WF6 (CI,GI)
Multiple Burst, 0.25/4.0 us, 5-160 A, 4500Voc
Safety Features
Door Interlocks
Safety Sockets
Outputs only connected during Transient
Active Module indicator LED
Voltage Present indicator LED
Environmental Operating Conditions
Operating temperature
+15°C to +35°C
Humidity
10-75%, non-condensing
Physical Specifications
Full-width ECAT plug-in module
CE Marking
Safety and EMC Directives
Model D568-L5
LTS Module for WF5A for Airbus/Boeing specifications.
For Cable Induction up to 1500V/1500A use 2 Model DCVI-1
Cable Induction Couplers.
2000V/2000A requires 3 DCVI-1 couplers.
General Specifications
WF5A (SS, MS)
40/120 µs, 50-2000 voltage & current.
Output impedance =1 Ohm
Safety Features
Door Interlocks
Safety Sockets
Outputs only connected during Transient
Active Module indicator LED
Voltage Present indicator LED
Environmental Operating Conditions
Temperature
+15°C to +35°C
Humidity
10-75%, non-condensing
Physical Specifications Full-width ECAT plug-in module
CE Marking
Safety and EMC Directives