Software/firmware options, Protection and safety, Ordering information available models – Atec Pacific-Power-115ASX-T User Manual
Page 4: Order example, Typical delivery items, 115asxt-upc1 power source

© 2012 Pacifi c Power Source, Inc. Subject to change without notice. #DS115ASX0912
17692 Fitch, Irvine, CA 92614 USA
Phone: +1 949.251.1800
Fax: +1 949.756.0756
Toll Free: 800.854.2433
E-mail: sales@pacifi cpower.com
www.pacifi cpower.com
Ordering Information
Available Models
With Manual Controller
With Programmable Controller
115ASX-115ASXT
General/Environmental
Mechanical Specifi cations
Hardware Options
/M7073
Safety Interlock Normally Open Contacts
/M99413
/P000828
/MXXXXX
Safety Interlock Normally Closed Contacts
15U rack enclosure, heavy duty vertical cabinet with casters
and rear screen. Ordered as separate line item.
Other factory specifi ed modifi cation
Software/Firmware Options
/S
RS-232 Interface, 38.4 KBps (std UPC-1)
/G
/Prog-z
/HAS
GPIB Interface, IEEE-488.2, (std UPC-12)
Harmonic Analysis and Synthesis
Programmable Output Impedance
/IR
In-Rush Meter. Capture and view peak in-rush current
values via front panel or remote interface (UPC-3 only).
Test MGR
UPC Test Manager License: Create, edit, and execute Test
sequences and reports. Ordered as separate line item.
Test SEQ
Avionics test sequences; DO-160, ABD-0100, ABD-0100 (A350),
Ordered as separate line item, Requires 'Test' Manager License.
Protection and Safety
Hardware
Programmable Current Limit
Programmable Current Protect
Over-current, short circuit, over- temperature
Allows the power source to operate in "constant voltage"
mode, interrupting output when specifi ed current protect
limit is exceeded.
A single RMS programmed, average responding, value
provided for all phases. Limits current by reducing output
voltage.
Model
Controller
Options
Input Voltage (V
IN
)
T-Ratio (115ASXT Only)
115ASX
UPC1M
UPC1
UPC12
See List Above
100 VAC ±10%, 47-63Hz
110 VAC ±10%, 47-63Hz
120 VAC ±10%, 47-63Hz
200 VAC ±10%, 47-63Hz
208 VAC ±10%, 47-63Hz
220 VAC ±10%, 47-63Hz
Ratio 1.5:1
Ratio 2.0:1
Ratio 2.5: 1
Order Example
115ASXT-UPC1/G, T= 2.0:1, V
IN
: 120VAC
•
1500VA, 1-Phase, AC Power Source with
optional transformer assembly and UPC-1
programmable controller.
•
Optional GPIB Interface
• 2.0:1
Transformer
Ratio
•
120VAC, 1 Phase Input Voltage
Typical Delivery Items
•
AC Power Source
•
English Manuals (AC Source and Controller)
•
UPC Studio Software - (Download)
•
UPC Interactive LabVIEW
TM
Libraries
(Download)
• Compliance
Certifi cate with Test data
•
CE Conformity Document (CE Models)
Temperature:
Humidity:
Cooling:
Altitude:
Heat Dissipation:
Audible Noise:
Agency Approvals:
0 - 95%, Non-condensing
Side forced air intake (120 CFM) with rear exhaust.
Operating: 6,500 Ft (1,981m)
Storage: 40,000 Ft (12,192 m)
750kBTU/ hr (Full kW Load)
65 dba Max @ 1 Meter
Safety UL 61010 -1
EN 61010 -1
EMC EN 61326 -1
Operating: 0° to 55° C
Storage: -10 ° to 70° C
Height
Depth
Weight
Mounting
Standard 19" rack (483mm). Cabinet options available.
115ASX: 5U (5.25", 133mm)
115ASX: 23" (584 mm)
115ASX - 70 lbs (32kg)
115ASXT 95 lbs (43kg)
115ASXT
115ASX-UPC1M
115ASXT-UPC1M
115ASX-UPC1 115ASX-UPC12
115ASXT-UPC1 115ASXT-UPC12
16.75" (425mm)
19" (483mm)
5U
(5.25",
133mm)
115ASXT-UPC1 Power Source.
230 VAC ±10%, 47-63Hz
240 VAC ±10%, 47-63Hz