320asx, Power factor rating curves, Input power requirements (47-63 hz) – Atec Pacific-Power-320ASX User Manual
Page 2: Output ratings 320asx, Asx power source specifications (pf = 1.0, v, 25% f.s.), Refer to the adjacent table
320ASX
Power Factor Rating Curves
Input Power Requirements (47-63 Hz)
Output Ratings
320ASX
Rated Power (VA)
1
Coupling Mode
Form
2
Output Voltage
3
V
rms
Max
(L-N/L-L)
Current
4
(A
rms
)
Frequency
Range
Input
Power
Unit Height
In/mm/U
Unit Weight
(Lbs/Kg)
2000
Direct
1Ш/2Ш
3Ш
150/300
150/260
20/12
7/Ш
15-1200
15-1200
1Ш
47-63Hz
5.25/133/3U
85 Lbs/39 kgs
NOTES:
1. Rated output power is based on a combination of nominal output voltage, rated current and load power factor. Values stated represent the maximum capabilites of a given model. Consult factory for assistance in determining specific unit
capabilities as they might apply to your application.
2. Unit is operable as single phase with dual range capability or as a three phase. Output voltage range and 1/3 conversions are selected by front panel or bus commands.
3. Vmax is output voltage with nominal input and full rated load applied.
4. Available current will vary with output voltage and power factor.
ASX Power Source Specifications (PF = 1.0, V
out
> 25% F.S.)
Output
Frequency
Line Regulation
Load Regulation
(Typ. 3 Phase)
Output Distortion
Ripple and Noise
Response Time
Full Power
15-1,200Hz Direct Coupled
0.1% max for a
±10% line change
3Ø direct coupled: 0.25% 15 to 400 Hz.,
0.50% 400 to 1,200 Hz.
0.25% THD
AVG
15 to 200 Hz
1.25% THD
AVG
200 to 1,200 Hz
-66dB
60 µsec typical,
10-90% load step
Input Voltage
Input Current
Recommended
Input service
100V 1Ø
±10%
22A
rms
25A
20A
rms
25A
18A
rms
25A
10A
rms
15A
9A
rms
15A
9A
rms
15A
110V 1Ø
±10%
120V 1Ø
±10%
200/V 1Ø
±10%
230V 1Ø
±10%
240V 1Ø
±10%
208V 1Ø
±10%
10A
rms
15A
M99211 Transformer Option
When combined with the 320ASX
,
the M99211
external Transformer assembly provides an additional
3Ø, high voltage, output range. Three high performance,
multi-tapped, autotransformers are assembled in a 19"
rack-mount chassis and are configured with either a 1.5,
2.0, 2.5:1 step-up ratio (specified at time of order).
Refer to the adjacent table
for rated output voltages
and currents when supplied with a nominal, 125 V/Ø
input signal. Complete M99211 modification description
available on request. Additional current/voltage ranges
available, consult factory.
M99211 Transformer Assembly Rear View
Rated Power (VA) Output Ratio
Nominal Output
Voltage
(L-N/L-L)
Current
A
rms/Ø
Dimensions
Weight
2000
1.5:1
2.0:1
2.5:1
187/325
250/433
312/540
3
2.25
1.8
3U
5.25 x19 x 23
133mm x 483mm x 584mm
70 Lbs
32 Kg
Load Regulation
(Typical)
Varies from 2 to 5% depending on
ratio. Improves to less than 0.1% with
external sense and CSC enabled
Rated Continuous load current as a function of Power Factor and Output Voltage-Nominal Input Line