beautypg.com

Amx power source models, Power source specifications, Mechanical specifications – Atec Pacific-Power-AMX Series User Manual

Page 6

background image

AMX POWER SOURCE MODELS

Notes:
1. All single phase units are operable with dual voltage ranges as listed. All three phase units are operable as single phase with dual voltage range capability or as three phase.
Output voltage ranges and 1f / 3f conversions are selected by front panel or bus command.
2. Output voltage ranges listed are for standard units. VMAX is achievable with nominal input voltage at full load. Other voltage ranges are
available with the output magnetics option.
3. Current ratings at 125 VRMS output.
4. Input power frequency is 47-63 Hz. Single Phase: 100, 110, 120, 200, 208, 220, 230, 240, VAC

±

10%. Three phase: 208, 220, 240, 380, 416 VAC

±

10%.

POWER SOURCE SPECIFICATIONS

Output Frequency: 20 to 5000 Hz. Full Power

Line Regulation:

0.1% max for a 10% line change

Load Regulation:

0.25% 20 to 2000 Hz.

0.5% 2000 to 5000 Hz.

Can be improved to less than 0.03%
with CSC engaged.

Output Distortion: 0.1% THD from 20 to 1000 Hz

0.25% THD from 1000 to 5000 Hz

Ripple and Noise: -72 dB

Response Time:

5

µ

sec. typical to a step load change. Small

signal band-width is 5 Hz. to 50 kHz, typical.

MECHANICAL SPECIFICATIONS

All models are designed for operation in 19 inch equipment racks.
Models above 1800 VA have side handles for ease of handling.

Mounting:

Standard 19 inch rack. Slide rails are available
as an option for all models.

Height:

See model table above for panel height.

Depth:

Will not exceed 24 inches from the front panel
to the rear of the chassis, including
connectors, handles and cabling.

Cooling:

Forced air, front or side intakes, rear exhaust
with auto fan speed control for low acoustic
noise operation.

POWER SOURCE SPECIFICATIONS

AMX Series Power sources can be equipped with output transformers to provide an alternate output voltage range. Selec-
tion of direct or transformer coupled range is performed by the controller via front panel or bus command. The standard
frequency range for transformer coupled outputs is 45 to 5000 Hz. Standard output ratios are 1.5:1, 2.0:1, and 2.5:1.
Transformer outputs are supplied internally or externally via a Magnetics Module. Consult the factory for additional
information regarding special output ranges not listed.

MODEL

105AMX

108AMX

112AMX

125AMX

140AMX

305AMX

308AMX

312AMX

1200

750

500

4000

2500

1200

750

500

OUTPUT

FORM

(Note 1)

RATED

P0WER

(VA)

OUTPUT

VOLTS MAX

(V

RMS

)

(Note 2)

OUTPUT

AMPS

(A

RMS

)

(Note 3)

OUTPUT

AMPS

(A

PK

)

INPUT

POWER

FORM

(Note 4)

PANEL

HEIGHT

(IN.)

WEIGHT

(LBS.)

135/270

4/2

40/20

6/3

40/20

40/20

10/5

90/45

5 1/4

65

65

110

170

65

65

70

65

5 1/4

10 1/2

14

5 1/4

5 1/4

5 1/4

5 1/4

140/70

45/15

15/Ш

45/15

15/Ш

45/15

15/Ш

20/10

32/16

4/2

1.5/Ш

6/2

2/Ш

10/3.3

3.3/Ш

135/270

150/300

150/300

135/270

135/270
135 L-N

135/270
135 L-N

150/300
150 L-N

318AMX

320AMX

330AMX

345AMX

360AMX

390AMX

3120AMX

12000

9000

6000

4500

3000

2000

1800

135/270
135 L-N

15/5

5/Ш

60/20

20/Ш

18/6

6/Ш

60/20

20/Ш

150/50

50/Ш

24/12

8/Ш

165/55

55/Ш

8 3/4

100

100

177

185

175 x 2

185 x 2

162

8 3/4

14

14

14

28

2 each x 14

28

2 each x 14

210/70

70/Ш

330/110

110/Ш

420/140

140/Ш

36/12

12/Ш

48/16

16/Ш

72/24

24/Ш

96/32

32/Ш

135/270
135 L-N

135/270
135 L-N

135/270
135 L-N

135/270
135 L-N

135/270
135 L-N

135/270

135 L-N

6