METERING

WAVEFORM CONTROL/ANALYSIS

V/I METER: ENTRY: 120.0
FREQ=60.00

Va=120.0

Vb=120.0

Vc=120.0

SENSE=INT

Vab=208.0 Vbc=208.0 Vca=208.0

MANUAL MODE Ia=06.00

Ib=06.22

Ic=06.15

POWER METER: PHASE A PHASE B PHASE C
KVA

0.720

0.746

0.738

KW

0.720

0.746

0.738

PF

1.000

1.000

1.000

AMPS METER: PHASE A PHASE B PHASE C
RMS

0.720

0.746

0.738

PEAK

1.044

1.119

1.383

CREST FACTOR

1.45

1.50

1.90

EDIT WAVEFORM: NUMBER=16

RANGE=2-22

STARTING PHASE ANGLE=0

0-359.5

°

ENDING PHASE ANGLE=0

0-359.5

°

VOLTAGE IN PERCENT=-100

(+/-)0-100%

WAVEFORM SYNTHESIS: WAVEFORM #2
HARMONIC:

2nd

3rd

4th

5th

6th

CONTENT:

.1%

0%

0%

0%

0%

ØANGLE:

0

°

0

°

0

°

0

°

0

°

ØA CURRENT THD=17.8 % OHD=17.8EHD=0.3%
HARMONIC:

2nd

3rd

4th

5th

6th

CONTENT:

.1%

17.8%

0%

0%

0%

ØANGLE:

0

°

0

°

0

°

0

°

0

°

FUNCTION KEY
PROVIDES ACCESS TO SPECIAL FUNCTIONS

SETUP: PRESS

1 FOR PROGRAM SETUP
2 FOR WAVEFORM SETUP
3 FOR GENERAL SETUP
4 FOR CALIBRATION MENU

PROGRAM SETUP

• Copy a program
• Delete a program
• Erase all memory,

reset CPU

WAVEFORM SETUP

• Edit a waveform
• Copy a waveform
• Waveform synthesis

GENERAL SETUP

• UPC setup
• LCD setup
• UPC status
• Power source status
• Range control
• Slew rate setup

CALIBRATION MENU

• Execute externally

referenced calibration

• View calibration

constants

SPECIAL FUNCTIONS ACCESSED
THROUGH UPC SETUP MENU

SENSE

Establishes either local or external
sense for metering and CSC.

CSC

Continuous Self Calibration –
provides for exceptional voltage
accuracy.

PROGRAM

Programmable output impedance

Z

°

dynamically compensates for
output transformer or line
distribution losses. Can simulate a
soft power grid.

TRANSITION Permits control of the transition

TIME

time when changing the output
voltage and frequency.

FREQUENCY Sets min and max programmable

LIMITS

frequency limits.

VOLTAGE

Sets min and max programmable

LIMITS

voltage limits.