Hardware options – Atec Pacific-Power-360AMX-AMXT User Manual
Page 4
360AMX-360AMXT
© 2013 Pacific Power Source, Inc. Subject to change without notice. #DS360AMX0713
17692 Fitch, Irvine, CA 92614 USA
Phone: +1 949.251.1800
Fax: +1 949.756.0756
Toll Free: 800.854.2433
E-mail: [email protected]
www.pacificpower.com
360AMXT-UPC3 Power Source with optional external high range transformer module.
19" (483mm)
8U
(14",
356mm)
19" (483mm)
3U
(5.25",
133mm)
Ordering Information
Available Models
With Manual Controller
360AMX-UPC3M
360AMXT-UPC3M
With Programmable Controller
360AMX-UPC3
360AMXT-UPC3
360AMX-UPC32 360AMXT-UPC32
General/Environmental
Mechanical Specifications
Software/Firmware Options
Protection and Safety
Order Example
360AMXT-UPC32, T= 2.0:1, V
IN
: 220/380VAC
•
4.5kVA, 3-Phase, AC Power Source with optional
transformer assembly and UPC-32 programmable
controller.
•
Standard GPIB Interface
•
2.0:1 Transformer Ratio
•
220/380VAC, 3 Phase Input Voltage
Typical Delivery Items
•
AC Power Source
•
English Manuals (AC Source and Controller)
•
UPC Studio Software - (Download)
•
UPC Interactive LabVIEW
TM
Libraries
(Download)
•
Compliance Certificate with Test data
•
CE Conformity Document (CE Models)
Model
Controller
Options
Input Voltage (V
IN
)
T-Ratio (360AMXT Only)
360AMX
360AMXT
UPC-3M
UPC-3
UPC-32
See List Above
208 VACΔ ± 10%, 47-63Hz
220VACΔ ± 10%, 47-63Hz
240VACΔ ± 10%, 47-63Hz
220/380VACΔ ±10%, 47-63Hz
240/416 VACΔ ±10%, 47-63Hz
Ratio 1.5:1
Ratio 2.0:1
Ratio 2.5:1
277/480 VACΔ ±10%,47- 63Hz
/Prog-Z
/HAS Harmonic Analysis and Synthesis
Programmable Output Impedance
/IR In-Rush Meter. Capture and view peak in-rush current
values via front panel or remote interface (UPC-3 only).
Test MGR UPC Test Manager License: Create, edit, and execute Test
sequences and reports. Ordered as separate line Item
Test SEQ Avionics test sequences; DO-160, ABD-0100, ABD-0100 (A350),
Ordered as separate line item, Requires 'Test' Manager License.
16.75" (426mm)
17" (432mm)
360AMXT Power Source with optional
external transformer module
Hardware
Programmable Current Limit
Programmable Current Protect
Over-current, short circuit, over- temperature
Allows the power source to operate in "constant voltage"
mode, interrupting output when specified current protect
limit is exceeded.
A single RMS programmed, average responding, value is
provided for all phases. Limits current by reducing output
voltage.
Temperature
Humidity
Cooling
Altitude
Heat Dissipation
Audible Noise
Agency Approvals
0 - 95%, Non-condensing
Front and side forced air intake (600 CFM) with rear exhaust.
Operating: 6,500 Ft (1,981m)
Storage: 40,000 Ft (12,192 m)
6.5kBTU/ hr (Full kW Load)
65 dba Max @ 1 Meter
Safety UL 61010 -1
EN 61010 -1
EMC EN 61326 -1
Operating: 0° to 55° C
Storage: -10 ° to 70° C
Height
Depth
Weight
Mounting
Standard 19" rack (483mm). Cabinet options available.
360AMX: 8U (14", 356mm)
Transformer Module: 3U (5.25", 133mm)
360AMX: 23.5" (597mm)
Transformer Module: 3U (5.25", 133mm)
(Approx. from front
panel to the rear of chassis.)
360AMX: 195 lbs (88.6kg)
Transformer Module: 125 lbs (56.8kg)
Hardware Options
/M99413
/PXXXXXX
/MXXXXX
Safety Interlock Normally Closed Contacts
Rack option available in different sizes, please contact Pacific
Power Source for details.
Other factory specified modification
/M7073 Safety Interlock Normally Open Contacts
/S
RS232 Interface. 38.4kbps, (Standard on UPC-3)
/G
GPIB Interface, IEEE-488.2. (Standard on UPC-32)