Power factor rating curves, Input power requirements (47-63 hz), Output ratings 360asx – Atec Pacific-Power-360ASX User Manual
Page 2: 360asxt, Asx power source specifications (pf = 1.0, v
360ASX-360ASXT
Power Factor Rating Curves
Input Power Requirements (47-63 Hz)
OUTPUT CURRENT - A
C A
MPS RMS
OUTPUT VOLTAGE - AC VOLTS RMS
150 140 130 120 110 100 90
80
70
60
50
40
30
300
150
280
140
260
130
240
120
220
110
200
100
180
90
160
80
140
70
120
60
100
50
80
40
60-2 Phase Mode
30-3 Phase Mode
84
72
60
48
36
24
12
0
28
24
20
16
12
8
4
0
OUTPUT VOLTAGE - AC VOLTS RMS
OUTPUT CURRENT - A
C A
MPS RMS
0.00 PF
1.00 PF
1.00 PF
0.00 PF
3 Phase
2 Phase
Single Phase Mode
Split and Three Phase Mode
Short term overloads to 60A are permitted. Operating time before thermal
shutdown or circuit breaker trip varies from seconds to several minutes
depending upon line and temperature conditions.
Short term overloads to 20A are permitted. Operating time before thermal
shutdown or circuit breaker trip varies from seconds to several minutes
depending upon line and temperature conditions.
Output Ratings
360ASX
Rated Power (VA)
1
Coupling Mode
Form
2
Output Voltage
3
V
rms
Max
(L-N/L-L)
Current
4
(A
rms
)
Frequency
Range
Input
Power
Unit Height
In/mm/U
Unit Weight
(Lbs/Kg)
6000
5
Direct
1Ш/2Ш
3Ш
132/264
132/228
48/16
16/Ш
15-1200
15-1200
3Ш
47-63Hz
8.75/222/5U
145 Lbs/66 kgs
360ASXT
Rated Power (VA)
1
Coupling Mode
Form
2
Output Voltage
3
V
rms
Max
(L-N/L-L)
Current
4
(A
rms
)
Frequency
Range
Input
Power
Unit Height
In/mm/U
Unit Weight
(Lbs/Kg)
6000
5
Direct
1Ш/2Ш
3Ш
132/264
132/228
48/16
16/Ш
15-1200
15-1200
3Ш
47-63Hz
360ASX
8.75/222/5U
Transformer Module
5.25/133/3U
360ASX
145 Lbs/66 Kgs
Transformer Module
125 Lbs/56.8 Kgs
Transformer 1.5:1
Transformer 2.0:1
Transformer 2.5:1
1Ш/2Ш
3Ш
1Ш/2Ш
3Ш
1Ш/2Ш
3Ш
198/396
198/343
264/528
264/457
330/600
330/572
32/11
11/Ш
24/8
8/Ш
19/6
6/Ш
45-1200
45-1200
45-1200
45-1200
45-1200
45-1200
NOTES:
1. Rated output power is based on a combination of nominal output voltage, rated current and load power factor. Values stated represent the maximum capabilites of a given model. Consult factory for assistance in determining specific unit
capabilities as they might apply to your application.
2. Unit is operable as single phase with dual range capability or as a three phase. Output voltage range and 1/3 conversions are selected by front panel or bus commands.
3. Vmax is output voltage with nominal input and full rated load applied.
4. Available current will vary with output voltage and power factor.
5. Source rated at 4kVA in 2Ø mode.
ASX Power Source Specifications (PF = 1.0, V
out
> 25% F.S.)
Rated Continuous load current as a function of Power Factor and Output Voltage-Nominal Input Line
* Power Source equipped with soft start feature. In-rush current at application of input power will not exceed recommended input service.
Input Voltage
Input Current
Recommended
Input service
208V 3ØΔ
±10%
20A
rms
30A
18A
rms
30A
16A
rms
25A
11A
rms
15A
11A
rms
15A
10A
rms
15A
Cost Option
Consult Factory
220V 3ØΔ
±10%
240V 3ØΔ
±10%
220/380V 3ØΔ
±10%
230/400V
±10%
240/416V
±10%
277/480V
±10%
Full Power
15-1,200Hz Direct Coupled
45-1,200 Hz Transformer Coupled
Output
Frequency
Line Regulation
0.1% max for a
±10% line
change
Load Regulation
(Typ. 3 Phase)
3Ø direct coupled: 0.25% 15 to 400 Hz.,
0.50% 400 to 1,200 Hz.
3Ø transformer coupled: 2 to 5% depending on ratio
Improves to less than 0.1% with external sense and
CSC enabled
Output Distortion
0.25% THD
AVG
15 to 200 Hz
1.25% THD
AVG
200 to 1,200 Hz
Ripple
and Noise
-66dB
Response Time
60 µsec typical,
10-90% load step