Xr series ii, Specifications, Experience you can rely on – Atec Magna-Power-XRII-Series-DatasheetЙ User Manual
Page 3: Agna-power electronics, Input, Environmental, Programming levels and accuracy of full scale, Monitoring levels and accuracy of full scale, Output, Physical

XR SERIES II
Specifications
M
AGNA-POWER
ELECTRONICS
M
E
P
Input
Nominal Voltage
3 phase, 3 wire + ground
208 VAC, 3φ (operating range 187 - 229 VAC)
240 VAC, 3φ (operating range 216 - 264 VAC)
380 VAC, 3φ (operating range 342 - 418 VAC)
415 VAC, 3φ (operating range 373 - 456 VAC)
440 VAC, 3φ (operating range 396 - 484 VAC)
480 VAC, 3φ (operating range 432 - 528 VAC)
1 phase, 2 wire + ground
(2 kW models only)
208 VAC, 1φ (operating range 187 - 229 VAC)
240 VAC, 1φ (operating range 216 - 264 VAC)
Frequency
50 Hz through 400 Hz
Power Factor
Greater than 92% at maximum power
Environmental
Operating Temperature
0 °C to 50 °C
Storage Temperature
-25 °C to 85 °C
Temperature Coefficient
0.04 / °C of maximum output current
Air Cooling
Side air inlet, rear exhaust
Programming Levels and Accuracy of Full Scale
Voltage
Set Point
Current
Set Point
OVT
Set Point
OCT
Set Point
Remote Analog
Programming Accuracy
± 0.50%
± 0.75%
± 0.50 %
± 0.75%
Digital
Programming Accuracy
± 0.50%
± 0.75%
± 0.50 %
± 0.75%
Remote Analog
Programming Levels
0 - 10.0 V
0 - 10 .0 V
0 - 10.0 V
0 - 10.0 V
Monitoring Levels and Accuracy of Full Scale
Output Voltage
Output Current
Remote Analog
Monitoring Accuracy
± 0.50%
± 0.75%
Digital
Monitoring Accuracy
± 0.50%
± 0.75%
Remote Analog
Monitoring Levels
0 - 10.0 V
0 - 10.0 V
Experience you can rely on.
Our products have evolved by listening to our customers and working
with them to find solutions to their problems. Our continual growth is
based upon our innovative engineering, superior manufacturing meth-
ods, and dedicated employees. Today, all engineering and manufactur-
ing is performed in Flemington, NJ.
Output
Ripple
See Model Charts
Line Regulation
Voltage Mode: ± 0.004% of full scale
Current Mode: ± 0.02% of full scale
Load Regulation
Voltage Mode: ± 0.01% of full scale
Current Mode: ± 0.04% of full scale
Load Transient Response
2 ms to recover within ±1% of regulated output, with a
50% to 100% or 100% to 50% step load change
Efficiency
≥ 86% (See Model Charts)
Stability
± 0.10% for 8 hrs. after 30 min. warmup
Isolation
Maximum input voltage to ground: ±2500 VAC
Maximum output voltage to ground: ±1000 VDC
User inputs and outputs: Referenced to earth ground
Maximum Slew Rate
Standard Models:
100 ms for output voltage change from 0 to 63%
100 ms for output voltage change from 0 to 63%
With High Slew Rate Option:
4 ms for output voltage change from 0 to 63%
8 ms for output voltage change from 0 to 63%
Bandwith
Standard Models:
3 Hz with remote analog voltage programming,
2 Hz with remote analog current programming.
With High Slew Rate Option:
90 Hz with remote analog voltage programming,
60 Hz with remote analog current programming.
Analog Output Impedances
Voltage output monitoring: 100 ohm,
Current output monitoring: 100 ohm,
+10V Ref: 1 ohm.
Physical
Power
(kW)
Size (H” x W” x D”)
Rack
Units
Weight
2 kW
4 kW
6 kW
8 kW
3.50 x 19 x 24 in (13.3 x 48.3 x 61.0 cm)
5.25 x 19 x 24 in (13.3 x 48.3 x 61.0 cm)
5.25 x 19 x 24 in (13.3 x 48.3 x 61.0 cm)
10.25 x 19 x 24 in (26.0 x 48.3 x 61.0 cm)
2U
2U
2U
2U
45 lbs (20.41 kg)
47 lbs (21.32 kg)
48 lbs (21.77 kg)
48 lbs (21.77 kg)
Control Limits
Remote Sense Limits
3% maximum voltage drop from output to load
Digital control inputs
and outputs limits
Input voltage: 0 to 5 V
Output voltage: 0 to 5 V, 5 mA drive capacity
Note: Specifications are subject to change without notice. For three-phase configurations,
specifications are line-to-neutral. Unless otherwise noted, input voltages and currents are
specified for three-phase configurations.