beautypg.com

Klp/klr output characteristics, Klp/klr physical specifications, Klp/klr general specifications – Atec Kepco-KLP Series User Manual

Page 4

background image

KEPCO, INC. • 131-38 Sanford Avenue • Flushing, NY 11355 USA

Tel: (718) 461-7000 • Fax: (718) 767-1102

Email: [email protected]www.kepcopower.com

KLP/KLR OUTPUT CHARACTERISTICS

SPECIFICATION

RATING/DESCRIPTION CONDITION

Stabilizer Type

CV/CC

Voltage/Current

Adjustment
Range

0-100% of rated voltage

No minimum

load required

Voltage

min-100% of rated current

(1)

Current

Source Effect

0.01% E

max

Over full

source range

Voltage

0.01% l

max

Current

Load Effect

0.02% E

max

Over full

rated load

Voltage

0.05% l

max

Current

Temperature
Effect

0.01%/ ºC

0.01%/ ºC

0-50ºC

Voltage

Current

Time Effect
(drift)

0.02%/24hr

After 30 minute

warmup

Voltage

0.02%/24hr

Current

Error Sensing

0.25 volts per wire

Above rated output

Rated output, any load

Transient
Recovery
for Load
Change

1% of E

max

50% load step 2A/

microsecond max

Excursion

2 msec

10% min load, Return

to 0.1% of setting

Recovery

Turnon/turnoff
Overshoot

2% max

Overvoltage
Protection

Programmable

20-120% of E

max

User selectable

recovery

(3)

Overcurrent
Protection

Programmable

72-120% of I

max

User selectable

recovery

(3)

Output Load
Wire Protection

Shutdown

Parallel Operation

Active load sharing within

5% of I

0

rated

User selectable

recovery

(3)

Up to 5 units

maximum

(4)

Rise Time

10 - 40V: 30 msec

75V: 40 msec

150V: 50 msec
300V: 60 msec
600V: 75 msec

0-E

max

rated load

(resistive)

Voltage

10 - 40V: 30 msec

75V: 40 msec

150V: 50 msec
300V: 60 msec
600V: 75 msec

0-I

max

rated load

(resistive)

Current

10 - 40V: 30 msec

75V: 40 msec

150V: 50 msec
300V: 60 msec
600V: 75 msec

I

max

-0

rated load

(resistive)

Current

Fall Time

10V: 475 msec
20V: 525 msec
36V: 825 msec
40V: 975 msec

75V: 2820 msec

150V: 4850 msec
300V: 4400 msec
600V: 3150 msec

E

max

-0, no load

(open circuit)

Voltage

No Load

(2)

10 - 40V: 30 msec

75V: 40 msec

150V: 50 msec
300V: 60 msec
600V: 75 msec

E

max

-0

rated load

(resistive)

Voltage

Rated Load

(1) See Model Table for minimum programmable current.
(2) For improved fall time performance consult factory for "R" (Rapid Output

Discharge) option.

(3) Either PROTECTED (output disabled and locked until source power

recycled) or SAFE (output disabled with unit programmed to last setting;
power recycling not needed for recovery).

(4) E-series are not Master/Slave capable.

Isolation
Voltage

10-40V: 100V d-c or peak

75-600V: 600V d-c or peak

Either output

terminal to ground

KLP/KLR PHYSICAL SPECIFICATIONS

SPECIFICATION

RATING/DESCRIPTION CONDITION

Weight

English

15 lbs

Shipping: 20 lbs

Metric

6.82 Kg

Shipping: 9.07 Kg

Dimensions

English

19" x 1.735" x 17.5"

Depth excluding

W x H x D

Metric

482.6mm x 44.45mm

connectors and

x 443.7mm

terminal blocks

Source Power

IEC 320-C19

250V a-c,

Connector

appliance inlet

16A (VDE)

125V a-c,

20A (UL)

Load

10-40V

Nickel-plated copper

Provision for

Connections

models

busbar with integral

safety covers

threaded stud

(1/4-20-1/2in.)

75-600V Shock-safe Euroblock,

models

single conductor size:

20-10 AWG

(0,5-5,0 mm

2

)

Analog

15 pin D-sub

Programming Port

Digital

Primary

Standard GPIB

IEEE 488.2 (GPIB)

Programming

connector

Ports

Secondary

9 pin D-sub

RS 232 (standard

models only)

Secondary

RJ45

LAN (E-Series

models only)

Feedback/

5 position low profile

Control Input

Euroblocks

(1) Either PROTECTED (output disabled and locked until source power

recycled) or SAFE (output disabled with unit programmed to last setting;
power recycling not needed for recovery) or AUTO (when fault clears,
unit automatically recovers to programming setpoints and output state
(enabled/disabled) as before fault was detected.

KLP/KLR GENERAL SPECIFICATIONS

SPECIFICATION

RATING/DESCRIPTION

CONDITION

Temperature Operating

-10 to +50°C

Rated load

+50 to +70°C

Derate current 3%

per °C over 50°C

Storage

-40 to +85°C

Cooling

3 internal d-c fans

Exhaust to the rear

Humidity

10 to 90% RH

Non-condensing

Shock

20g, 11msec ± 50%

Non-operating

half sine

Vibration

5-10Hz

10mm double amplitude

3-axes, non-operating

10-55 Hz

2g

3-axes, non-operating

Altitude

sea level to 10,000 ft.

0-3,000 ft: 100%,

linear derating

to 70% of power

at 10,000 ft.

Loss of

Shutdown

User selectable

Source Power

recovery (1)

Overtemperature

Shutdown

User selectable

Protection

recovery (1)

Fan Failure

Shutdown

Recovery requires

power recycling

Withstand

Input-

2121V d-c

25°C, 65% RH

Voltage

Chassis

(all models)

Output-

1250V d-c

Chassis

(10V-40V models)

2121V d-c

(75V-600V models)

Input-

2500V d-c

Output

(10V-40V models)

4242V d-c

(75V-600V models)