beautypg.com

Atec Kepco-KLP Series User Manual

Page 3

background image

FEATURES

KLP: Provides 1200W output power over a hyperbolic output power envelope,
resulting in full output power availability over the range of 8V, 150A to 600V, 2A

KLR: Provides up to 2400W output power via a conventional rectangular output
power envelope, resulting in full output power at model limits only

Switch mode topology for cool, efficient operation

GPIB and isolated analog programming included on all models

Standard models have an RS-232 interface

E-Series models replace the RS-232 interface with an Ethernet (RJ-45) connector
supporting LAN (LXI certified for KLP)

KLP: 1U panel height at 1200 watts

KLR: 1U panel height at 2400 watts

Front to back air flow allows full power operation without spacers between supplies

KLP: Operates over universal a-c mains voltage range of 90 - 264V a-c with PFC

KLR: Operates over a-c mains voltage range of 180 - 264V a-c with PFC

KLP: Stud-style output power terminals for LV models (10V, 20V, 36V), and
Euroblock output power terminals for HV models (75V, 150V, 300V, 600V)

KLR: Stud-style output power terminals for LV models (20V, 40V), and
Euroblock output power terminals for HV models (75V, 150V, 300V)

KEPCO, INC. • 131-38 Sanford Avenue • Flushing, NY 11355 USA • Tel: (718) 461-7000 • Fax: (718) 767-1102

Email: [email protected]www.kepcopower.com

KLP/KLR INPUT SPECIFICATIONS

SPECIFICATION

RATING/DESCRIPTION

CONDITION

SERIES KLP

SERIES KLR

a-c Voltage

Nominal

100-240V a-c

200-240V a-c

Single phase

Range

90-265V a-c

180-265V a-c

Wide range

Input

Nominal Range

50-60 Hz

50-60 Hz

Frequency

Maximum

45-440 Hz

45-440 Hz

Increased leakage above 66 Hz

Power Factor (PF)

Typical

0.99

0.99

Meets EN 61000-3-2

Maximum

120V a-c

13A rms

N/A

Rated load (1200W)

Input Current

240V a-c

6.5A rms

N/A

Rated load (1200W)

230V a-c

N/A

12A rms

Rated load (2400W)

Inrush Current

265V a-c

40A

40A

Peak

132V a-c

20A

N/A

Peak

Input Fusing

Circuit breaker

Circuit breaker

2-line

Low a-c Protection

87V a-c self protected

175V a-c self protected

User-selectable recovery

(1)

Output Holdup

Typical

10 milliseconds

5 milliseconds

Ride through

Leakage

115V a-c, 60 Hz

1.2mA max

N/A

Current

230V a-c, 50 Hz

2.3mA max

2.3mA max

(1) Either PROTECTED (output disabled and locked until source power recycled) or SAFE (output disabled with unit programmed to last setting; power recycling

not needed for recovery) or AUTO (when fault clears, unit automatically recovers to programming setpoints and output state (enabled/disabled) as before fault
was detected.

NOTE: Contact Kepco Applications Engineering for d-c input.

MARKETS AND APPLICATIONS

• Aerospace and Satellite Test

• Telecom and IT Industry

• Automated Test Equipment

• Factory Automation

• QC Testing

• Burn-in

• Solar

• Water Purification

• Thermal Process Control

• Chemical Processing

• Semiconductor Manufacturing

• Battery Charging and Testing

• Electroplating, Sputtering and Coating

• New Energy R&D