Printer Output:
Supports several thermal
and impact printers.
Output data in numeric or
graphic (“strip chart”) format.
T
RANSDUCER
S
PECIFICATIONS
.
Wetted Ultrasonic
Flow Transducers:
Temperature Range:
Standard: –40° to 212°F
(–40° to 100°C).
Optional (overall range):
–310° to 932°F (–190° to 500°C).
Pressure Range:
Standard: 0 to 3000 psig
(0.1013 to 20 MPa).
Optional: Higher pressures on request.
Materials:
Standard: 316 SS.
Optional (for isolating Pan-Adapta
®
Plugs): Titanium, Hastelloy, Monel,
Duplex, CPVC, PVDF and others.
Process Connections:
Standard: 1-inch NPTM or
3/8-inch NPTM.
Optional: RF flanged, socket weld,
fuse bond and others.
Mounting:
Spoolpiece, hot tap or cold tap.
Housing:
Standard: None.
Optional:
Weatherproof (NEMA 4, IP65).
Explosionproof (Div I, Class I,
Group C & D).
Flameproof (EEx d IIC T4 to T6).
Submersible.
Clamp-On Ultrasonic
Flow Transducers:
Temperature Range:
Standard: –40° to 140°F (–40° to 60°C).
Optional (overall range): –310° to
572°F (–190° to 300°C).
Mounting:
SS Chain or strap, welded or
magnetic clamping fixtures.
Housing:
Standard: None.
Optional:
Weatherproof (NEMA 4, IP65).
Explosionproof (Div I, Class I,
Group C & D).
Flameproof (EEx d IIC T4 to T6).
Submersible.
Note: Transducers (wetted and
clamp-on), spoolpieces and
clamping fixtures for special
applications are available.
Consult Panametrics for details.
Temperature Transducers:
Loop powered 3-wire platinum
RTDs; Clamp-on and wetted
(thermowell) types are available.
Accuracy:
0.15°C, wetted RTDs
(matched pairs).
Range:
–4° to 500°F (–20° to 260°C).
P
IPE
S
IZE
& M
ATERIALS
.
Wetted Transducers:
Materials:
All metals and most plastics.
(Consult Panametrics for
concrete, glass, and cement.)
Pipe Sizes, Transit-Time Mode:
Inside diameter (ID) 0.04 to 200 in.
(1 mm to 5 m) and larger.
Clamp-On Transducers:
Materials:
All metals and most plastics.
(Consult Panametrics for
concrete, composite materials
and highly corroded or
lined pipes.)
Pipe Sizes, Transit-Time Mode:
Outside diameter (OD) 0.5 to 200 in.
(12.7 mm to 5 m) and larger.
Pipe Sizes, TransFlection Mode:
Outside diameter (OD) 2 to 200 in.
(5 cm to 5 m).
Pipe Wall Thickness:
Up to 3 in. (76.2 mm).
A
VAILABLE
O
PTIONS
.
Flow Measurement
Configurations:
Standard: Transit-time mode.
Optional:
Transit-time and TransFlection
modes (PT868-R).
2-channel version (2PT868).
Energy Equipment:
Dual RTD transmitter; two 4- to 20-mA
transmitters with input for 3-wire RTD
(100
Ω
Pt) and terminals for 4- to
20-mA output; and 6-ft cable.
Fast Charger Module:
External fast charger module for
charging spare battery packs
with standard power supply/
charger. 2- to 3-h charge time.
Thickness Measuring Mode:
Transducer:
Panametrics dual element
transducer.
Pipe Thickness Range:
0.05 to 3 in. (1.3 to 76.2 mm).
Pipe Materials:
Most standard metal and
plastic pipe materials.
Accuracy:
± 1% typical or ± 0.002 in.
(± 0.05 mm).
Display Resolution:
0.001 in. (0.025 mm).
Thermal Exposure:
Continuous operation to 37°C (100°F).
Intermittent operation to 260°C
(500°F) for 10 sec followed by
air cooling for 2 min.
Printer Option:
Thermal printer with rechargeable
battery, 6-ft cable and 120-VAC
or 240-VAC charger.
PC Interface Software:
Instrument Data Manager (IDM) soft-
ware links PT868 with computer
or PC. Includes 3.5-in. diskettes,
interconnection cable (please
specify type), and manual.