Flowmeter—from panametrics – Atec Panametrics-Olympus-PT868 User Manual

Page 5

background image

Energy Accuracy:

The accuracy of the energy

measurement is a combi-
nation of the accuracy of
the associated flow and
temperature measurements.

Transit-Time Mode:
1% of reading typical for

calibrated systems.

TransFlection Mode:
2% of reading typical for

calibrated systems.

Fluid Types:

Transit-Time Mode:
Acoustically conductive fluids,

including most clean liquids
and many with entrained
solids or gas bubbles. Maxi-
mum void fraction depends
on transducer, interrogation
carrier frequency, path length
and pipe configuration.

TransFlection Mode:
Multiphase fluids, including raw

sewage, sludge, slurries, tar
sands, oil-water-gas mixtures,
acoustically attenuating
liquids and other demanding
applications.

E

LECTRICAL

S

PECIFICATIONS

.

Internal Batteries:

Batteries:
4 C-size NiCd high-energy

rechargeable batteries.

Battery Life, Transit-Time Mode:
6 to 8 h of continuous

operation typical.

Battery Life, TransFlection Mode:
3 to 4 h of continuous

operation typical.

Recharge Time:
16 to 20 h using external charger.

Power Supply:

Input:
100/120/200/260 VAC ± 10%,

50/60 Hz, 5 W maximum.

Output:
12 VDC unregulated.
Note: The PT868 may also be pow-

ered or charged by any regulated
DC source that provides spike-free
voltage of 10 to 28 VDC.

Environmental:

Operating Temperature:
14° to 122°F (–10° to 50°C).

Storage Temperature:
14° to 122°F (–10° to 50°C).

O

VERALL

S

PECIFICATIONS

.

Hardware Configuration:

Channel Options:
Single channel.
Dual channel (for 2 pipes or

2 paths on a single pipe).

Mode Options:
Transit-time.
Transit-time plus TransFlection.

Dimensions:
Size: 5 x 9 x 2.3 in.

(12.7 x 22.9 x 5.8 cm).

Weight: 2.2 lb (1 kg).

Flow Accuracy:

Transit-Time Mode:
Pipe diameter (ID) > 6 in. (150 mm):
Velocity > 1 ft/s (> 0.3 m/s), 2% of

reading typical; 0.5 to 1% of read-
ing with calibration. See note.

Velocity

1 ft/s (

0.3 m/s), ± 0.03 ft/s

(± 0.01 m/s). See note.

Pipe diameter (ID)

6 in. (150 mm):

Velocity > 1 ft/s (> 0.3 m/s), 2 to 5%

of reading typical. See note.

Velocity

1 ft/s (

0.3 m/s),

± 0.15 ft/s (± 0.05 m/s). See note.

TransFlection Mode:
Pipe diameter (ID) 2 in. (50 mm)

and larger:

Velocity > 1 ft/s (> 0.3 m/s),± 5% of

reading typical; ± 2% of reading
with calibration. See note.

Note: Specifications assume a fully

developed flow profile. Accuracy for
both modes depends on pipe size.

Range:

Transit-Time Mode:
–40 to 40 ft/s (–12.2 to 12.2 m/s ).

TransFlection Mode:
–1 to –30 ft/s (–0.3 to –9.1 m/s).
1 to 30 ft/s (0.3 to 9.1 m/s).
± 1 to 15 ft/s (0.3 to 4.6 m/s).

Rangeability:

Transit-Time Mode:
400:1.

TransFlection Mode:
30 to 1.

Repeatability:

Transit-Time Mode:
Wetted transducers:

± 0.2% of full scale.

Clamp-on transducers:

± 0.2 to 0.5% of full scale.

TransFlection Mode:
Clamp-on transducers:

± 0.5% of full scale.

Note: To ensure maximum battery

life, storage temperature exceed-
ing 95°F (35°C) is not recom-
mended for long periods of time.

Operating Modes:

Flow Measurement:
Transit-time mode with clamp-on

or wetted flow transducers.

TransFlection mode with clamp-on

flow transducers.

Energy Measurement:

To calculate energy flow rate, use

the external loop-powered RTD
transmitter (2CHRT).

Input/Output Specifications:

Keypad:
30-key tactile feedback

membrane keypad.

Display:
64 x 128 pixel LCD graphic

display with backlight.

Printer/ Terminal:
One RS232 port for printer,

terminal or PC.

Analog Input:
Two 4- to 20-mA analog inputs with

switchable 16-V supply for loop
powered temperature transmitters.

Analog Output:
Two 0/4- to 20-mA current outputs

(550

max. load).

Acoustic:
One pair of LEMO

®

coaxial

transducer connectors.

Cable & Length:
Cable length 25 ft (8 m) standard.

Up to 1000 ft (305 m) optional
with extension cables.

O

PERATIONAL

S

PECIFICATIONS

.

Site Parameter Programming:
Menu driven operator interface using

keypad and “soft” function keys.

On-line help functions

including pipe tables.

Storage for saving parameters

for up to 20 sites.

Data Logging:
Memory capacity to log over

43,000 flow data points.

Keypad programmable for log units,

update times, start and stop time.

Totalizers:
Forward and reverse with

stopwatch timer.

Display Functions:
Graphic display shows flow in

numeric or graphic format.

Also displays logged data.

Flowmeter—From Panametrics.