AMX Power Systems
Ordering Information
Software/Firmware Options
/Prog-Z
/HAS Harmonic Analysis and Synthesis
Programmable Output Impedance
Test MGR UPC Test Manager License: Create, edit, and execute Test
sequences and reports. Ordered as separate line Item
Test SEQ Avionics test sequences; DO-160, ABD-0100, ABD-0100 (A350),
Ordered as separate line item, Requires 'Test' Manager License.
Mechanical Specifications
Height
Depth
Weight
Mounting Standard 19" rack (483mm).
**Cabinet options available, see Hardware Option Below.
See System Configuration Table for required rack
height by configuration
Units: 23.5” (597mm)
Transformer Module: 3U (5.25”, 133mm) (Approx. from front
panel to the rear of chassis).
Depends on system configuration
Contact Pacific Power Source or your local Pacific Power Source representative for assistance with specific system con-
figurations.
17692 Fitch, Irvine, CA 92614 USA
Phone: +1 949.251.1800
Fax: +1 949.756.0756
Toll Free: 800.854.2433
E-mail: [email protected]
www.pacificpower.com
General/Environmental
Temperature
Humidity
Cooling Per Unit
Altitude
Heat Dissipation Per Unit
Audible Noise
Agency Approvals
0 - 95%, Non-condensing
Operating: 6,500 Ft (1,981m)
Storage: 40,000 Ft (12,192 m)
6.5kBTU/ hr (Full kW Load)
65 dba Max @ 1 Meter
CE Mark:
Safety UL 61010 -1
EN 61010 -1
EMC EN 61326 -1
Operating: 0° to 55° C
Storage: -10 ° to 70° C
Front and side forced air intake (600 CFM) with rear exhaust.
Automatic Fan Speed Control for low acoustic noise and
extended fan life.
Hardware
Programmable Current Limit
Programmable Current Protect
Over-current, short circuit, over- temperature
Allows the power source to operate in "constant voltage" mode,
interrupting output when specified current protect limit is
exceeded.
A single RMS programmed, average responding, value is pro-
vided for all phases. Limits current by reducing output voltage.
Protection and Safety
Hardware Options
/M99413
/PXXXXXX
Safety Interlock Normally Closed Contacts
Rack option available in different sizes. Available standard
cabinet sizes are:
/M7073 Safety Interlock Normally Open Contacts
/S RS232 Interface. 38.4kbps
/G GPIB Interface, IEEE-488.2. (Standard on UPC-12 and UPC-32)
40” 23U Inside rack height
49” 28U Inside rack height
61” 35U Inside rack height
Available integration levels:
Basic Installation only. AMX units installed in cabinet, no wir-
ing, no rear screen.
Carriage Return Full Integration. Installation in cabinet, input
and output wiring, terminal blocks, rear screen.
IEC 61000-4 AC Immunity Test Sequences. Includes 4-11, 4-14,
4-27, 4-28 and 4-34. Excludes 4-13 Option.
© 2012 Pacific Power Source, Inc. Specifications subject to change without notice.
DS#6AMXMSTSLV1212
Page 6 of 6
IEC-AC-4XX
SCU/UPC32-413 IEC 61000-4-13 Inter Harmonic Generator. Required to run 4-13
tests. Includes 4-13 software.