beautypg.com

Amx power systems, Software/firmware options, Mechanical specifications – Atec Pacific-Power-AMX Series User Manual

Page 6: General/environmental, Protection and safety hardware options

background image

AMX Power Systems

Ordering Information

Software/Firmware Options

/Prog-Z

/HAS Harmonic Analysis and Synthesis

Programmable Output Impedance

Test MGR UPC Test Manager License: Create, edit, and execute Test

sequences and reports. Ordered as separate line Item

Test SEQ Avionics test sequences; DO-160, ABD-0100, ABD-0100 (A350),

Ordered as separate line item, Requires 'Test' Manager License.

Mechanical Specifications

Height

Depth

Weight

Mounting Standard 19" rack (483mm).

**Cabinet options available, see Hardware Option Below.

See System Configuration Table for required rack
height by configuration

Units: 23.5” (597mm)

Transformer Module: 3U (5.25”, 133mm) (Approx. from front
panel to the rear of chassis).

Depends on system configuration

Contact Pacific Power Source or your local Pacific Power Source representative for assistance with specific system con-

figurations.

17692 Fitch, Irvine, CA 92614 USA

Phone: +1 949.251.1800

Fax: +1 949.756.0756

Toll Free: 800.854.2433

E-mail: [email protected]

www.pacificpower.com

General/Environmental

Temperature

Humidity

Cooling Per Unit

Altitude

Heat Dissipation Per Unit

Audible Noise

Agency Approvals

0 - 95%, Non-condensing

Operating: 6,500 Ft (1,981m)
Storage: 40,000 Ft (12,192 m)

6.5kBTU/ hr (Full kW Load)

65 dba Max @ 1 Meter

CE Mark:
Safety UL 61010 -1
EN 61010 -1
EMC EN 61326 -1

Operating: 0° to 55° C
Storage: -10 ° to 70° C

Front and side forced air intake (600 CFM) with rear exhaust.

Automatic Fan Speed Control for low acoustic noise and

extended fan life.

Hardware

Programmable Current Limit

Programmable Current Protect

Over-current, short circuit, over- temperature

Allows the power source to operate in "constant voltage" mode,
interrupting output when specified current protect limit is
exceeded.

A single RMS programmed, average responding, value is pro-
vided for all phases. Limits current by reducing output voltage.

Protection and Safety

Hardware Options

/M99413

/PXXXXXX

Safety Interlock Normally Closed Contacts

Rack option available in different sizes. Available standard

cabinet sizes are:

/M7073 Safety Interlock Normally Open Contacts

/S RS232 Interface. 38.4kbps

/G GPIB Interface, IEEE-488.2. (Standard on UPC-12 and UPC-32)

40” 23U Inside rack height

49” 28U Inside rack height

61” 35U Inside rack height

Available integration levels:
Basic Installation only. AMX units installed in cabinet, no wir-

ing, no rear screen.
Carriage Return Full Integration. Installation in cabinet, input

and output wiring, terminal blocks, rear screen.

IEC 61000-4 AC Immunity Test Sequences. Includes 4-11, 4-14,

4-27, 4-28 and 4-34. Excludes 4-13 Option.

© 2012 Pacific Power Source, Inc. Specifications subject to change without notice.

DS#6AMXMSTSLV1212

Page 6 of 6

IEC-AC-4XX

SCU/UPC32-413 IEC 61000-4-13 Inter Harmonic Generator. Required to run 4-13

tests. Includes 4-13 software.