beautypg.com

Amx power systems, Waveform control, Output metering – Atec Pacific-Power-AMX Series User Manual

Page 5

background image

AMX Power Systems

The UPC Controller

is a highly versatile one, two, or three

phase oscillator/signal generator designed to control

any of Pacific Power’s AC Power Sources. Only the full

featured UPC-12 or UPC-32 Controller is offered for use

with the 3 single or three phase parallelable AMX models.

Controller Models

Output Control Specifications

Total Control, Metering, and Analysis of AC Power- Simple, Intuitive Operation

Features

UPC-12

UPC-32

Output Modes

Waveform Library

Transient Functions

Program Library

Programmable Current Limit

Programmable Current Protect

Programmable Phase Angle

CSC (Continuous Self-Calibration)

Remote Interface

Std
Opt

Waveform Synthesis/Analysis

Prog. Output Impedance

DRM Link-Synchronization

Line Synchronization

1Ø, & 2Ш

1Ш, 2Ш, & 3Ø

Sine +

15 Editable

Sine +

15 Editable

YES, 99 Steps

YES, 99 Steps

99 Programs

99 Programs

YES

YES

YES

YES

YES, 0 to 359°

YES, 0 to 359°

YES

YES

GPIB

RS-232

OPTIONAL

OPTIONAL

OPTIONAL

OPTIONAL

OPTIONAL

OPTIONAL

Frequency

UPC-12

UPC-32

Voltage

Phase Angle

±0. 5°

Current Limit

20-5,000Hz

(1)

4 Significant Digits

±0.01% of full scale

0 - 150/375

0.1V/ 0.5V

0.5% of full scale (CSC Disabled)
±0. 05% referenced to Internal Meter (CSC Enabled)

0 - 359°

± 1°

±1% F.S.

Function of the number of units in parallel.

0.05% F.S.

Resolution

Accuracy

Range (l-n)

Resolution

Accuracy

Range

Resolution

Accuracy

Range

Resolution

Accuracy

ØB and ØC relative to ØA

Range

Program Edit and Function Key

Ouput Control, Slew, and enable Keys

Parameter Control

4 x 16 Character LCD

Using the front panel keyboard and display,

all control-

ler models provide for selection of power source output

mode, coupling, voltage, and frequency. Selecting the

correct UPC controller for a given application varies with

your test requirement, desired features, and price.

Both the UPC-12 and UPC-32 Controllers

are available

with either RS-232 or GPIB remote interface. Commands

are structured in accordance with SCPI (Standard Com-

mands for Programmable Instruments).

External Inputs/Outputs

Analog Auxilary Input

AM-Amplitude Modulation

Sync Outputs Zero Crossing

Transient Trigger

Transient Pedestal

Output Clock

Positive Zero Crossing (0°) of Phase A analog output

Pulse at the start of a transient event.

TTL True when a transient is in progress

UPC-32, TTL level 1024 x output frequency

±10 Vdc (20Vpk-pk) modulates the output voltage

±100%

One input per phase. Z

IN

= 600 Ω

Each phase is algebraically summed with UPC waveform

and amplified 25X to the direct coupled output.

±10Vpk (20Vpk-pk). One input per phase. Z

IN

= 600 Ω

Waveform Control

Waveform Synthesis

(/HAS Option)

Creates waveform by entering magnitude as %

of fundamental and specified phase angle for

2nd through the 51st harmonic

Reports waveform harmonic content and phase

angle relative to the fundamental for the 2nd

through the 51st harmonic as Total, Odd, and

Even harmonic distortion

(/HAS Option)

Waveform Analysis

GPIB

RS-232

20-5,000Hz

Output Metering

Ammeter

UPC-12

UPC-32

Power Meter

True Watts and
Volt-Amps each
phase

10.00-99.99 Hz, 0.01 Hz
100.0-999.9 Hz, 0.1 Hz
1,000-5,000 Hz, 1 Hz

0.01A front panel

Freq. Display

Crest Factor

±0.25% of rdg.

50-500Hz, ± 0.1% F.S.

20-5,000 Hz, ± 0.5% F.S.

1.0 Watt or VA front panel

Ratio: Apk/A

RMS

Calculated and displayed to three

digits following the decimal

± 1 % full range

20.00-5,000Hz

Voltmeter

0-354 V

L-N

, 708V

L-L

0.1V

front panel

50-500Hz, ± 0.25% of rdg.

± 0.1% F.S.

20-5,000 Hz, ± 0.5% F.S.

Power Factor

Calculated and displayed to three

digits following the decimal point.

± 1 % full range

True V

RMS

each

phase

True A

RMS

and

Apk each phase

± 1% full range

Ratio : kW

mtr

/kVA

mtr

Range

Resolution

Accuracy

Range

Resolution

Accuracy

Range

Resolution

Accuracy

Resolution

Accuracy

Resolution

Accuracy
Range

Resolution

Accuracy

± 0.01% full range

Function of the number of units in parallel.

Function of the number of units in parallel.

OPTIONAL

OPTIONAL

© 2012 Pacific Power Source, Inc. Specifications subject to change without notice.

DS#6AMXMSTSLV1212

Page 5 of 6