beautypg.com

Amx power systems, Output power – Atec Pacific-Power-AMX Series User Manual

Page 4

background image

AMX Power Systems

Single Phase Parallable AMX Models

Three Phase Parallable AMX Models

Output Power

Number of Master

Units

Master Model Number

Number of

Slave Units

Slave Model Number

Max. Current

Per Phase

Number of Chassis

Total Height

13.5kVA

(3 x 4.5kVA)

1

345AMXT-UPC32/MST

2

345AMXT/SLV

36A @ 125V

18A @ 250V

3 PS + 3 XFMR

33U

2

345AMXT-UPC32/MST

1

345AMXT/SLV

3

345AMXT-UPC32/MST

0

-

18kVA

(3x 6kVA)

1

360AMXT-UPC32/MST

2

360AMXT/SLV

48A @ 125V

24A @ 250V

3 PS + 3 XFMR

33U

2

360AMXT-UPC32/MST

1

360AMXT/SLV

3

360AMXT-UPC32/MST

0

-

24kVA

(4 x 6kVA)

1

360AMXT-UPC32/MST

3

360AMXT/SLV

64A @ 125V

32A @ 250V

4 PS + 4 XFMR

44U

2

360AMXT-UPC32/MST

2

360AMXT/SLV

3

360AMXT-UPC32/MST

1

360AMXT/SLV

4

360AMXT-UPC32/MST

0

-

30kVA

(5 x 6kVA)

1

360AMXT-UPC32/MST

4

360AMXT/SLV

80A @ 125V

40A @ 250V

4 PS + 4 XFMR

33U

2

360AMXT-UPC32/MST

3

360AMXT/SLV

3

360AMXT-UPC32/MST

2

360AMXT/SLV

4

360AMXT-UPC32/MST

1

360AMXT/SLV

5

360AMXT-UPC32/MST

0

-

Output Power

Number of Master

Units

Master Model Number

Number of

Slave Units

Slave Model Number

Max. Current

Number of Chassis

Total Height

8kVA

(2 x 4kVA)

1

140AMXT-UPC12/MST

1

140AMXT/SLV

64A @ 125V

32A @ 250V

2 PS + 2 XFMR

22U

2

140AMXT-UPC12/MST

0

-

12kVA

(2 x 6kVA)

1

160AMXT-UPC12/MST

1

160AMXT/SLV

96A @ 125V

48A @ 250V

2 PS + 2 XFMR

22U

2

160AMXT-UPC12/MST

0

-

18kVA

(3 x 6kVA)

1

160AMX-UPC12/MST

2

160AMX/SLV

144A @ 125V

48A @ 250V

3 PS

24U

2

160AMX-UPC12/MST

1

160AMX/SLV

3

160AMX-UPC12/MST

0

-

24kVA

(4 x 6kVA)

1

160AMX-UPC12/MST

3

160AMX/SLV

192A @ 125V

64A @ 250V

4 PS

32U

2

160AMX-UPC12/MST

2

160AMX/SLV

3

160AMX-UPC12/MST

1

160AMX/SLV

4

160AMX-UPC12/MST

0

-

Addition or deletion of power source chassis is easily performed by the user in field. The standard AMX-Series features,

such as automatic output form selection, extensive output metering, etc. remain intact.

Note that only like models may be paralleled with each other. That is, only 345AMX chassis may be paralleled with other

345AMX chassis, 140AMX with 140 AMX, etc. All Master units are master/slave selectable from rear panel switch.

Typical System Configuration Examples

Flexible Re-Configuration

© 2012 Pacific Power Source, Inc. Specifications subject to change without notice.

DS#6AMXMSTSLV1212