6 Fluke Calibration 1586A Super-DAQ Precision Temperature Scanner
PRT/RTD resistance accuracy
Accuracy is given as % of measurement or ohms, whichever is greater. Basic accuracy is for 4-wire PRT/RTD. When using
3-wire PRT/RTD add 0.013 Ω to the accuracy specification for internal resistance mismatch and voltage offset if using
Channel 1, or add 0.05 Ω if using channels x01 through x20. If the environment temperature is outside the specified range,
multiply the temperature coefficient numbers by the temperature deviation and add to the accuracy specification.
Range
Sample Rate
DAQ-STAQ Multiplexer
and Channel 1
High-Capacity Module
T.C./ °C Outside
18 °C to 28 °C
0 Ω to 400 Ω
Slow
0.002 % or 0.0008 Ω
0.003 % or 0.003 Ω
0.0001 % or 0.0008 Ω
Medium
0.002 % or 0.002 Ω
0.003 % or 0.003 Ω
0.0001 % or 0.0008 Ω
Fast
0.002 % or 0.005 Ω
0.003 % or 0.006 Ω
0.0001 % or 0.0008 Ω
400 Ω to 4 kΩ
Slow
0.004 % or 0.06 Ω
0.006 % or 0.06 Ω
0.0001 % or 0.008 Ω
Medium
0.004 % or 0.1 Ω
0.006 % or 0.1 Ω
0.0001 % or 0.008 Ω
Fast
0.004 % or 0.18 Ω
0.006 % or 0.18 Ω
0.0001 % or 0.008 Ω
PRT/RTD temperature accuracy
Accuracy is for 4-wire 100 Ω nominal PRT/RTD. When using 3-wire PRT/RTD add 0.039 °C to the accuracy specification
for internal resistance mismatch and voltage offset if using Channel 1, or add 0.15 °C if using channels x01 through x20.
If the environment temperature is outside the specified range, multiply the temperature coefficient number by the tem-
perature deviation and add to the accuracy specification. Linear interpolation may be used between points in the table.
Specifications do not include sensor accuracy. The practical range of temperature measurement depends on the sensor
and characterization.
Sample Rate
Temperature
DAQ-STAQ Multiplexer and
Channel 1
High-Capacity Module
T.C./ °C Outside
18 °C to 28 °C
Slow
−200 °C
0 °C
300 °C
600 °C
0.002 °C
0.005 °C
0.012 °C
0.02 °C
0.008 °C
0.008 °C
0.018 °C
0.03 °C
0.002 °C
0.003 °C
0.006 °C
0.01 °C
Medium
−200 °C
0 °C
300 °C
600 °C
0.005 °C
0.005 °C
0.012 °C
0.02 °C
0.008 °C
0.008 °C
0.018 °C
0.03 °C
0.002 °C
0.003 °C
0.006 °C
0.01 °C
Fast
−200 °C
0 °C
300 °C
600 °C
0.013 °C
0.013 °C
0.014 °C
0.02 °C
0.015 °C
0.015 °C
0.018 °C
0.03 °C
0.002 °C
0.003 °C
0.006 °C
0.01 °C
PRT/RTD measurement characteristics
Range
Temperature Display Resolution
Source Current
Slow / Medium
Sample Rate
Fast
Sample Rate
0 Ω to 400 Ω
0.001 °C
0.01 °C
±1 mA
400 Ω to 4 kΩ
0.001 °C
0.01 °C
0.1 mA
Thermistor
Temperature range
−200 °C to 400 °C (depending on the sensor)
Resistance range
0 Ω to 1 MΩ