beautypg.com

Ftb-8510b packet blazer, Fc-1x/2x, Testing (1x and 2x) – Atec EXFO-FTB-8510B User Manual

Page 9: General specifications

background image

FTB-8510B Packet Blazer

FIBRE CHANNEL INTERFACES

FIBRE CHANNEL FUNCTIONAL SPECIFICATIONS

FC-1X/2X

Wavelength (nm)

850

1310

1550

Tx level (dBm)

–9 to –3

–9.5 to –3

0 to 5

Rx level sensitivity (dBm)

–18 at FC-2X
–20 at FC-1X

–21 at FC-2X
–22 at FC-1X

–21 at FC-2X
–22 at FC-1X

Maximum reach

550 m on 50/125 µm MMF at FC-1X
300 m on 50/125 µm MMF at FC-2X
300 m on 62.5/125 µm MMF at FC-1X
150 m on 62.5/125 µm MMF at FC-2X

10 km

80 km

Transmission bit rate (Gbit/s)

1.0625 to 2.125

1.0625 to 2.125

1.0625 to 2.125

Reception bit rate (Gbit/s)

1.0625 to 2.125

1.0625 to 2.125

1.0625 to 2.125

Tx operational wavelength range (nm)

830 to 860

1270 to 1360

1540 to 1570

Measurement accuracy (uncertainty)

frequency (ppm)
optical power (dB)

±4.6
±2

±4.6
±2

±4.6
±2

Maximum Rx before damage (dBm)

6

6

6

Jitter compliance

ANSI FC-PI-2

ANSI FC-PI-2

ANSI FC-PI-2

FC classification

ANSI FC-PI-2

ANSI FC-PI-2

ANSI FC-PI-2

Laser type

VCSEL

Fabry-Perot

DFB

Eye safety

Class 1

Class 1

Class 1

Connector

LC

LC

LC

Transceiver type

SFP

SFP

SFP

TESTING (1X AND 2X)

BERT

Unframed, framed FC-1, framed FC-2.

Patterns (BERT)

PRBS 2E31-1, 2E23-1, 2E20-1, 2E15-1, 2E11-1, 2E9-1 CSPAT, CRPAT, CJTPAT, and 10 user-defined 32 bits patterns.

Error insertion

Bit error, symbol error, oversize error, CRC error, undersize error.

Error measurement

Bit error, symbol error, oversize error, CRC error, undersize error, performance management (G.821 and G.826).

Alarm insertion

LOS, pattern loss, link down.

Alarm detection

LOS, pattern loss, link down.

Buffer-to-buffer credit testing

Buffer-to-buffer credit estimation based on latency.

Latency

Round-trip latency measurement.

ADDITIONNAL TEST AND MEASUREMENT FUNCTIONS (1X AND 2X)

Power measurement

Support optical power measurement, displayed in dBm.

Frequency measurement

Supports clock frequency measurements (i.e., received frequency and deviation of the input signal clock from nominal frequency).

Frequency offset measurement

Range
Resolution
Accuracy (uncertainty)

±120 ppm
1 ppm
±4.6 ppm

Frequency offset generation

Range
Resolution
Accuracy (uncertainty)

±120 ppm
1 ppm
±4.6 ppm

GENERAL SPECIFICATIONS

Size (H x W x D)

96 mm x 25 mm x 280 mm

(3

3

/

4

in x 1 in x 11 in)

Weight (without transceivers)

0.5 kg

(1.1 lb)

Temperature
operating
storing

0 °C to 40 °C
–40 °C to 60 °C

(32 °F to 104 °F)
(–40 °F to 140 °F)