Ftb-8510b packet blazer, Fc-1x/2x, Testing (1x and 2x) – Atec EXFO-FTB-8510B User Manual
Page 9: General specifications
FTB-8510B Packet Blazer
FIBRE CHANNEL INTERFACES
FIBRE CHANNEL FUNCTIONAL SPECIFICATIONS
FC-1X/2X
Wavelength (nm)
850
1310
1550
Tx level (dBm)
–9 to –3
–9.5 to –3
0 to 5
Rx level sensitivity (dBm)
–18 at FC-2X
–20 at FC-1X
–21 at FC-2X
–22 at FC-1X
–21 at FC-2X
–22 at FC-1X
Maximum reach
550 m on 50/125 µm MMF at FC-1X
300 m on 50/125 µm MMF at FC-2X
300 m on 62.5/125 µm MMF at FC-1X
150 m on 62.5/125 µm MMF at FC-2X
10 km
80 km
Transmission bit rate (Gbit/s)
1.0625 to 2.125
1.0625 to 2.125
1.0625 to 2.125
Reception bit rate (Gbit/s)
1.0625 to 2.125
1.0625 to 2.125
1.0625 to 2.125
Tx operational wavelength range (nm)
830 to 860
1270 to 1360
1540 to 1570
Measurement accuracy (uncertainty)
frequency (ppm)
optical power (dB)
±4.6
±2
±4.6
±2
±4.6
±2
Maximum Rx before damage (dBm)
6
6
6
Jitter compliance
ANSI FC-PI-2
ANSI FC-PI-2
ANSI FC-PI-2
FC classification
ANSI FC-PI-2
ANSI FC-PI-2
ANSI FC-PI-2
Laser type
VCSEL
Fabry-Perot
DFB
Eye safety
Class 1
Class 1
Class 1
Connector
LC
LC
LC
Transceiver type
SFP
SFP
SFP
TESTING (1X AND 2X)
BERT
Unframed, framed FC-1, framed FC-2.
Patterns (BERT)
PRBS 2E31-1, 2E23-1, 2E20-1, 2E15-1, 2E11-1, 2E9-1 CSPAT, CRPAT, CJTPAT, and 10 user-defined 32 bits patterns.
Error insertion
Bit error, symbol error, oversize error, CRC error, undersize error.
Error measurement
Bit error, symbol error, oversize error, CRC error, undersize error, performance management (G.821 and G.826).
Alarm insertion
LOS, pattern loss, link down.
Alarm detection
LOS, pattern loss, link down.
Buffer-to-buffer credit testing
Buffer-to-buffer credit estimation based on latency.
Latency
Round-trip latency measurement.
ADDITIONNAL TEST AND MEASUREMENT FUNCTIONS (1X AND 2X)
Power measurement
Support optical power measurement, displayed in dBm.
Frequency measurement
Supports clock frequency measurements (i.e., received frequency and deviation of the input signal clock from nominal frequency).
Frequency offset measurement
Range
Resolution
Accuracy (uncertainty)
±120 ppm
1 ppm
±4.6 ppm
Frequency offset generation
Range
Resolution
Accuracy (uncertainty)
±120 ppm
1 ppm
±4.6 ppm
GENERAL SPECIFICATIONS
Size (H x W x D)
96 mm x 25 mm x 280 mm
(3
3
/
4
in x 1 in x 11 in)
Weight (without transceivers)
0.5 kg
(1.1 lb)
Temperature
operating
storing
0 °C to 40 °C
–40 °C to 60 °C
(32 °F to 104 °F)