14

Handheld Spectrum Analyzer (HSA)

N9340B

Symbol rate range :

Modulation depth/index

200 Hz to 100 kHz

Range :

Accuracy :

Displayed resolution :

10% to 95%

0.1%

±4% of reading nominal

ASK measurement

Symbol rate range :

FSK deviation

1 kHz to 100 kHz

Range :

Accuracy :

Displayed resolution :

1 kHz to 400 kHz

0.01 Hz

±4% of reading nominal ß > 1 and ß < 4

FSK measurement

*

*

ß is the ratio of frequency deviation to symbol rate (deviation/rate)