beautypg.com

Amplitude specifications, Continued spurious responses, Residual responses – Atec Agilent-8560EC-65EC Series User Manual

Page 6: Display range, Scale fidelity, Reference level range

background image

Amplitude Specifications,

continued

Spurious responses

General spurious responses

(Mixer level –40 dBm)

< (–75 + 20 x logN)

1

dBc

Second harmonic distortion

Input

signal

Mixer

level Distortion SHI

20 MHz to 1.45 GHz

–40 dBm

≤ –79 dBc

2

+39 dBm

2

1.45 GHz to 2 GHz

–10 dBm

3

≤ –85 dBc

3

+75 dBm

3

2 GHz to 13.25 GHz

8562E, 8563E

–10 dBm

≤ –100 dBc

+90 dBm

8564E, 8565E

–10 dBm

≤ –90 dBc

+80 dBm

13.25 GHz to 25 GHz

–10 dBm

≤ –90 dBc

+80 dBm

Third order intermodulation distortion

(Two –30 dBm signals, ≥ 1 kHz apart)

Mixer

level Distortion TOI

20 MHz to 2.9 GHz

–30 dBm each

≤ –82 dBc

4

+11 dBm

2.9 GHz to 6.46 GHz

–30 dBm each

≤ –90 dBc

+15 dBm

6.46 GHz to 26.8 GHz

–30 dBm each

≤ –75 dBc

+7.5 dBm

26.8 GHz to 50 GHz

–30 dBm each

≤ –85 dBc (nominal)

+12.5 dBm (nominal)

Image

responses

Mixer

level

10 MHz to 26.8 GHz

–10 dBm

–80 dBc

26.8 GHz to 50 GHz

–30 dBm

–60 dBc

Multiple and out-of-band responses

Mixer

level

10 MHz to 26.8 GHz

–10 dBm

–80 dBc

6

26.8 GHz to 50 GHz

–30 dBm

–55 dBc

Residual responses

≤ –90 dBm, for the range from 200 kHz to 6.46 GHz, no input signal, 0 dB input attenuation

Display range

Viewing area

Color display, approximately 9.6 cm (v) x 13 cm (h)

Scale calibration

10 x 10 divisions

Log scale

10, 5, 2, 1 dB per division

Linear scale

10% of reference level per division

Scale fidelity

Incremental

Maximum

Log range

0 to –90 dB

0 to –90 dB

RBW ≥ 300 Hz

±0.1 dB/dB

±0.85 dB

RBW ≤ 100 Hz

±0.2 dB/2 dB

±0.85 dB

5

Linear range

±3% of reference level

Reference level range

Log, adjustable in 0.1 dB steps

30 Hz to 31.15 GHz

–120 to +30 dBm

31.15 GHz to 50 GHz

–115 to +30 dBm

Linear, adjustable in 1% steps

30 Hz to 31.15 GHz

2.2 mV to 7.07 V

31.15 GHz to 50 GHz

3.98 mV to 7.07 V

6

1. Excluding display-related sidebands at multiples of 60 Hz

2. Agilent 8561EC: distortion –72 dBc, SHI +32dBm

3. Agilent 8561EC: mixer level –20 dBm, distortion –72 dBc, SHI +52 dBm

4. Agilent 8561EC –78 dB distortion with two –30 dBm signals, 9 dBm TOI

5. Maximum for 0 to –100 dB is ±1.5 dB

6. For 8565EC only:-72 dBc at center frequency range between 20 and

26.5 GHz with RF input frequencies greater than 40 GHz.