Summary of Features on Standard Instrument

The following features are standard with the
Agilent 35670A:

Instrument modes

FFT analysis

Histogram/time

Correlation analysis

Time capture

Measurement

Frequency domain
Frequency response

Power spectrum

Linear spectrum

Coherence

Cross spectrum

Power spectral density

Time domain (oscilloscope mode)
Time waveform

Autocorrelation

Cross-correlation Orbit

diagram

Amplitude domain
Histogram, PDF, CDF

Trace coordinates

Linear magnitude

Unwrapped phase

Log magnitude

Real part

dB magnitude

Imaginary part

Group delay

Nyquist diagram

Phase Polar

Trace units

Y-axis amplitude: combinations of units, unit value,
calculated value, and unit format describe y-axis amplitude
Units: volts, g, meters/sec

2

, inches/sec

2

, meters/sec,

inches/sec, meters, mils, inches, pascals, Kg, N, dyn, lb,
user-defined EUs
Unit value: rms, peak, peak-to-peak
Calculated value: V, V

2

, V

2

/Hz, √Hz, V

2

s/Hz (ESD)

Unit format: linear, dB’s with user selectable dB reference,
dBm with user selectable impedance.
Y-axis phase: degrees, radians
X-axis: Hz, cpm, order, seconds, user-defined

Display formats

Single
Quad
Dual upper/lower traces
Small upper and largelower
Front/back overlay traces
Measurement state
Bode diagram
Waterfall display with skew, -45 to 45 degrees
Trace grids on/off
Display blanking
Screen saver

Display scaling

Autoscale Selectable reference
Manual Scale

Linear or log X-axis

Input range tracking

Y-axis log

X & Y scale markers with expand and scroll

Marker functions

Individual trace markers
Coupled multi-trace markers
Absolute or relative marker
Peak search
Harmonic markers
Band marker
Sideband power markers
Waterfall markers
Time parameter markers
Frequency response markers

Signal averaging (FFT mode)

Average types (1 to 9,999,999 averages)
RMS

Time exponential

RMS exponential

Peak hold

Time

Averaging controls

Overload reject
Fast averaging on/off
Update rate select
Select overlap process percentage
Preview time record

Measurement control

Start measurement
Pause/continue measurement

Triggering

Continuous (Freerun)
External (analog or TTL level)
Internal trigger from any channel
Source synchronized trigger
GPIB trigger
Armed triggers
Automatic/manual
RPM step
Time step
Pre- and post-trigger measurement Delay

Tachometer input:

±4 V or ±20 V range
40 mv or 200 mV resolution
Up to 2048 pulses/rev
Tach hold-off control