Specifications

Table A-1 lists the specifications for the different load models. Specifications
indicate warranted performance in the 25 °C ± 5 °C region of the operating
temperature range. Specifications apply to normal and transient modes unless
otherwise noted.

Table A-1

N3302A

N3303A

N3304A

N3304-J01

Special
order option

N3305A

N3306A

N3307A

Input ratings

Current

0–30 A

0–10 A

0–60 A

0–60 A

0–60 A

0–120 A

0–30 A

Voltage

0–60 V

0–240 V

0–60 V

0–80 V

0–150 V

0–60 V

0–150 V

Maximum power @ 40 °C

1

150 W

250 W

300 W

300 W

500 W

600 W

250 W

Input characteristic

Operating contour

Derated current detail

Voltage

Full
scale

Full
scale

0

Max. power contour

Current

Voltage

Full
scale

Full
scale

3

2

1

0

All specifications apply

Slew rate limitations apply
(see Table A-2)

Current

N3302A

N3303A

N3304A

N3304-J01

Special
order option

N3305A

N3306A

N3307A

Specified current @ low voltage operation

2.0 V

30 A

10 A

60 A

60 A

60 A

120 A

30 A

1.5 V

22.5 A

7.5 A

45 A

45 A

45 A

90 A

22.5 A

1.0 V

15 A

5 A

30 A

30 A

30 A

60 A

15 A

0.5 V

7.5 A

2.5 A

15 A

15 A

15 A

30 A

7.5 A

0 V

0 A

0 A

0 A

0 A

0 A

0 A

0 A

1. Maximum continuous power available is derated linearly from 100% of maximum at 40 °C, to 75% of maximum at 55 °C.

Table A-1 states that maximum current is available down to 2 volts. Typically,
however under normal operating conditions, the load can sink the maximum
current down to the following voltages:

N3302A

N3303A

N3304A

N3304-J01

Special
order option

N3305A

N3306A

N3307A

Typical minimum operating voltage @ full scale current

1.2 V

1.2 V

1.2 V

1.2 V

1.4 V

1.4 V