beautypg.com

Specifications, California instruments – Atec California-Instruments-2003RP User Manual

Page 3

background image

Specifications

California
Instruments

Total Customer Satisfaction

is the goal of all California In-
struments’ employees. It is the
driving force behind everything
we do. This not only affects the
product that you purchase from
California Instruments, but ev-
erything about your interface
with the company. Our applica-
tions engineers are ready to
assist you with your AC power
application. With over 35 years
of experience designing and
building precision AC power
supplies, chances are we can
meet your needs and exceed
your expectations. The same
dedication to customer satis-
faction you will find in our ap-
plications group also perme-
ates our modern manufactur-
ing facility where our products
are carefully built. No unit
leaves our factory without be-
ing thoroughly tested to ensure
quality, reliability and conform-
ance to specifications.

Parameter

2003RP

Unit

Controller

Type

Programmable

Controls

Digital Encoders

Readouts

dual 4 digit LCD’s

Output

No. of Phases

3 (A, B, C)

Phase angles

A = 0°, B = 240°, C = 120°

AC Power

Max. per phase

675

VA

Load Connection

floating neutral

Rear panel terminal block

Voltage

Ranges

High / Low

0-270/0-135

V

RMS

Accuracy

2

16 Hz - 100 Hz

± 0.1

% FS

100 Hz - 2000 Hz

± 0.2

% FS

Resolution

0.1

V

Load Regulation

2

remote sense, 16 - 500 Hz

± 0.1

% FS

Line Regulation

10 % Line change

± 0.02

% FS

T.H.D.

2

(into a

16 Hz - 100 Hz

0.5 typ./ 1.0 max.

%

resistive load)

100 Hz - 2000 Hz

1.0 typ./ 2.0 max.

%

Output Noise

< 0.1 typ.

V

RMS

Frequency

Range

(see V-F rating chart)

16-5000

Hz

Accuracy

± 0.02

%

Resolution

16.00 Hz - 80.00 Hz

0.01

Hz

80.1 Hz - 800.0 Hz

0.1

Hz

800 Hz - 5000 Hz

1

Hz

Current per Phase (see I-V rating chart)

RMS Current

High / Low V range

2.5 / 5.0

A

RMS

Peak Current

High / Low V range

7.5 / 15.0

A

Protection

Adj. Current limit

Resolution

0.1

A

RMS

Modes

Const. Current or Const. Volt

Over Temperature

Over Voltage

Input

Connection

Rear panel terminal block

Line Voltage

2 wire + GND

96 - 127 V or 187 - 253 V

V

RMS

Line Current

< 35

A

RMS

Line Frequency

47 - 440

Hz

Holdup Time

10

ms

Isolation

Input to Chassis/Output

1350 / 2200

V

Measurements

2

- Specifations valid from 300 - 500 Hz, Phase Selectable. (* Requires Option -OP1)

Current

Range Low / High

0.000-4.000 / 0.00-6.00

A

RMS

Accuracy

0.2 % FS + 0.3 % rdng

Resolution

0.001 / 0.01

A

RMS

Peak Current*

Range Low / High

0.00-12.00 / 0.0-20.0

A

Accuracy

0.5 % FS + 0.5 % rdng

Resolution

0.01 / 0.1

A

Voltage*

Range

0.0 - 300.0

V

RMS

Accuracy

0.1 % FS + 0.05 % rdng

Resolution

0.1

V

RMS

Power*

Range

0.0-800.0

W

Accuracy

0.5 % FS

Resolution

0.2

W

Power Factor*

Range

0.00 - 1.00

Resolution

0.01

Remote Control

(* Requires Option -OP1)

Interface*

RS232C and IEEE-488

IEEE Functions

SH1, AH1, T8, L3, RL2

RS232C settings

19200,8,n,1

Command Language

SCPI

Remote Inhibit*

Output shut down

TTL in, active low

BNC

Function Strobe*

On V or F change

TTL out, active low

BNC

Physical

Dimensions

HxWxD

5.25 x 19 x 22

inches

HxWxD

133 x 483 x 560

mm

Weight (net)

85 / 38.3

lbs / kg

Vibration and Shock

Designed to meet NSTA-1A

Temperature

Operating

0 to 40

° C

Storage

- 40 to + 85

° C

Voltage, Current and Frequency rating charts

Note 1: All specifications are for L-N. Phase angle specifications are valid under balanced load conditions only. Ambient temp. 23° ± 5° C.
Note 2: Supplementary specifications apply outside indicated frequency ranges.

3: At 400 Hz input, nominal line voltage minimum required.