Specifications, California instruments – Atec California-Instruments-2003RP User Manual
Page 3
Specifications
California
Instruments
Total Customer Satisfaction
is the goal of all California In-
struments’ employees. It is the
driving force behind everything
we do. This not only affects the
product that you purchase from
California Instruments, but ev-
erything about your interface
with the company. Our applica-
tions engineers are ready to
assist you with your AC power
application. With over 35 years
of experience designing and
building precision AC power
supplies, chances are we can
meet your needs and exceed
your expectations. The same
dedication to customer satis-
faction you will find in our ap-
plications group also perme-
ates our modern manufactur-
ing facility where our products
are carefully built. No unit
leaves our factory without be-
ing thoroughly tested to ensure
quality, reliability and conform-
ance to specifications.
Parameter
2003RP
Unit
Controller
Type
Programmable
Controls
Digital Encoders
Readouts
dual 4 digit LCD’s
Output
No. of Phases
3 (A, B, C)
Phase angles
A = 0°, B = 240°, C = 120°
AC Power
Max. per phase
675
VA
Load Connection
floating neutral
Rear panel terminal block
Voltage
Ranges
High / Low
0-270/0-135
V
RMS
Accuracy
2
16 Hz - 100 Hz
± 0.1
% FS
100 Hz - 2000 Hz
± 0.2
% FS
Resolution
0.1
V
Load Regulation
2
remote sense, 16 - 500 Hz
± 0.1
% FS
Line Regulation
10 % Line change
± 0.02
% FS
T.H.D.
2
(into a
16 Hz - 100 Hz
0.5 typ./ 1.0 max.
%
resistive load)
100 Hz - 2000 Hz
1.0 typ./ 2.0 max.
%
Output Noise
< 0.1 typ.
V
RMS
Frequency
Range
(see V-F rating chart)
16-5000
Hz
Accuracy
± 0.02
%
Resolution
16.00 Hz - 80.00 Hz
0.01
Hz
80.1 Hz - 800.0 Hz
0.1
Hz
800 Hz - 5000 Hz
1
Hz
Current per Phase (see I-V rating chart)
RMS Current
High / Low V range
2.5 / 5.0
A
RMS
Peak Current
High / Low V range
7.5 / 15.0
A
Protection
Adj. Current limit
Resolution
0.1
A
RMS
Modes
Const. Current or Const. Volt
Over Temperature
√
Over Voltage
√
Input
Connection
Rear panel terminal block
Line Voltage
2 wire + GND
96 - 127 V or 187 - 253 V
V
RMS
Line Current
< 35
A
RMS
Line Frequency
47 - 440
Hz
Holdup Time
10
ms
Isolation
Input to Chassis/Output
1350 / 2200
V
Measurements
2
- Specifations valid from 300 - 500 Hz, Phase Selectable. (* Requires Option -OP1)
Current
Range Low / High
0.000-4.000 / 0.00-6.00
A
RMS
Accuracy
0.2 % FS + 0.3 % rdng
Resolution
0.001 / 0.01
A
RMS
Peak Current*
Range Low / High
0.00-12.00 / 0.0-20.0
A
Accuracy
0.5 % FS + 0.5 % rdng
Resolution
0.01 / 0.1
A
Voltage*
Range
0.0 - 300.0
V
RMS
Accuracy
0.1 % FS + 0.05 % rdng
Resolution
0.1
V
RMS
Power*
Range
0.0-800.0
W
Accuracy
0.5 % FS
Resolution
0.2
W
Power Factor*
Range
0.00 - 1.00
Resolution
0.01
Remote Control
(* Requires Option -OP1)
Interface*
RS232C and IEEE-488
IEEE Functions
SH1, AH1, T8, L3, RL2
RS232C settings
19200,8,n,1
Command Language
SCPI
Remote Inhibit*
Output shut down
TTL in, active low
BNC
Function Strobe*
On V or F change
TTL out, active low
BNC
Physical
Dimensions
HxWxD
5.25 x 19 x 22
inches
HxWxD
133 x 483 x 560
mm
Weight (net)
85 / 38.3
lbs / kg
Vibration and Shock
Designed to meet NSTA-1A
Temperature
Operating
0 to 40
° C
Storage
- 40 to + 85
° C
Voltage, Current and Frequency rating charts
Note 1: All specifications are for L-N. Phase angle specifications are valid under balanced load conditions only. Ambient temp. 23° ± 5° C.
Note 2: Supplementary specifications apply outside indicated frequency ranges.
3: At 400 Hz input, nominal line voltage minimum required.