Atec California-Instruments-6000LS User Manual
Page 7

Note (1): All input voltage specifications are for Line-to-Line three phase, delta or wye. Model 3000Ls (208 V input) can be
operated on 230 V L-N single-phase if needed.
Options
Option Matrix:
Note that some options are mutually exclusive as indicated in the table below. An o
means the options can be combined. An
x
means they cannot.
13500Ls
13.5 kVA
1/3
208-230V ±10 %
13500Ls-400
13.5 kVA
1/3
400V ±10%
18000Ls
18 kVA
1/3
208-230V ±10 %
C prefix Cabinet System. Installed and pre-wired in 19
cabinet.
Input Options
-400
400 Volt Line-to-Line AC input.
[Not available on 6000Ls model or 12000Ls and 18000Ls Systems]
Output Options
-AX
1
Auxiliary outputs, 26 VAC, 5 VAC. Limits upper frequency to 800 Hz.
-HV
1
135/270 V output range.
-EHV
1
200/400 V output range.
-HF
1
Extends upper frequency limit. See HF table.
HF Table
Models
Max. Freq.
3000Ls, 4500Ls, 6000Ls
5000 Hz
9000Ls/2, 12000Ls/2, 13500Ls/2, 18000Ls/2 2000 Hz
-LF
1
Limits output frequency to 500 Hz.
Note 1: See option matrix
Keypad Options
-KPD
Upgraded keypad control panel.
Controller Options
-160
RTCA/DO-160D, Change 2, EuroCAE-14D and Airbus test firmware [Section 16, AC only]
-704
Mil-Std 704 Rev D and E test firmware. [AC only]
-ABD
Airbus Directive 0100.1.8 tests. [AC only]. Requires -ADV and use of Windows PC and included LxGui software.
-ADV
Advanced feature set. Adds arbitrary waveform generation and harmonic analysis of voltage and current.
-GPIB
GPIB interface and APE programming language
-LAN
Ethernet Interface
-MB
Multi-box. Adds controller to auxiliary chassis of multi-chassis systems.
-MODE Adds phase mode selections for -3 models.
-L22
Locking Knobs
-LKM
1
Clock and Lock Master
-LKS
1,2
Clock and Lock Auxiliary
-LNS
2
Line Sync.
-EXS
2
External Sync.
Note 1: See option matrix
Note2 : -LKS, -LNS and -EXS are mutually exclusive and with Ext Trig function.
Cabinet Options
-RMS
Rack-mount slides. Recommended for rack-mount applications.
C prefix Cabinet System. Installed and pre-wired in 19
cabinet.
HF LF HV EHV LKM LKS EXS AX
HF
-
x
o
o
x
x
x
x
LF
x
-
o
o
o
o
o
o