Ets terrasas – Atec Elgar-ETS Series User Manual
Page 5

858.458.0223
ETS TerraSAS
ETS Model
Numbers
Model Number
Output islolation (V)
Output leakage capacitance (nF)
Voc (V)
Isc (A)
Power rating Input Voltage (AC)
MPP Update Rate
ETS60X14C-PVF
±1000
45
60
14
840W
100-240VAC
250Hz (*)
ETS80X10.5C-PVF
±1000
45
80
10.5
840W
100-240VAC
250Hz (*)
ETS150X5.6C-PVF
±1000
45
150
5.6
840W
100-240VAC
250Hz (*)
ETS80X15C-PVE
±600
300
80
15
1200W
110/220VAC
120Hz
ETS600X8C-PVF
±600
200
600
8.3
5kW
208VAC
200Hz
ETS600X8D-PVF
±600
200
600
8.3
5kW
400VAC
200Hz
ETS600X8E-PVF
±600
200
600
8.3
5kW
480VAC
200Hz
ETS600X17C-PVF
±600
320
600
16.7
10kW
208VAC
200Hz
ETS600X17D-PVF
±600
320
600
16.7
10kW
400VAC
200Hz
ETS600X17E-PVF
±600
320
600
16.7
10kW
480VAC
200Hz
ETS600X25C-PVF
±600
440
600
25
15kW
208VAC
200Hz
ETS600X25D-PVF
±600
440
600
25
15kW
400VAC
200Hz
ETS600X25E-PVF
±600
440
600
25
15kW
480VAC
200Hz
ETS1000X10C-PVF
±1400
4.5
1000
10
10kW
208VAC
200Hz
ETS1000X10D-PVF
±1400
4.5
1000
10
10kW
400VAC
200Hz
ETS1000X10E-PVF
±1400
4.5
1000
10
10kW
480VAC
200Hz
(*) these models also support power optimizers
Listed part numbers refer to the end user package that contains the PV Simulator, a full set of accessories, cables and user manual in print form. Please contact the factory
to order PV simulators with a customized accessory kit.
295