Options, Options (all models), Other solutions – Atec EM-Test-Netwave-1-Phase Series User Manual
Page 4
DATA SHEET > NetWave Series 1-phase > 20130304
TECHNICAL DETAILS
OPTIONS
OPTIONAL ACCESSORIES (FOR NETWAVE 7 ONLY)
MT-NetWave
Three-phase matching transformer,
input voltage 3x200V,
output voltage 3x400V,
in separate cubicle
IT-NetWave
Three-phase isolation transformer,
input voltage 3x200 or 3x400V,
output voltage 3x400V,
with 25HU rack (with space to also
house a DPA 500N).
This option is required to use the
NetWave 7 for aircraft and MIL
standard testing.
OPTIONAL SOFTWARE FOR MODELS NETWAVE 7.X
NWLicense 1
Software license for DO-160
standard
(only for models NetWave 7.2/7.3)
NWLicense 2
Software license for MIL-STD-704
standard
(only for models NetWave 7.2/7.3)
NWLicense 3
Software license for AIRBUS
standards
(only for models NetWave 7.2/7.3)
NWLicense 4
Software license for analysis
functions as min., max., average and
...,
power and harmonic measurement,
(requires the option "NWBoard")
NWLicense 5
Software license for BOEING
standards
(only for models NetWave 7.2/7.3)
OPTIONS (ALL MODELS)
NW-BOARD MEASURING MODULE
Voltage
25V, 50V, 100V, 250V and 500V,
unipolar or bipolar
Current
7A, 15A, 30A, 70A and 150A,
unipolar or bipolar
Resolution
16 Bit
Accuracy
Voltage: better than 0.2%
Current: better than 0.5%
Frequency range
DC - 50kHz
Sample rate
5Hz - 100kHz, selectable
Memory
Min. 40GB on hard disk,
File size max. 1GB
OTHER SOLUTIONS
OTHER MODELS
NetWave Series
(3-phase)
Three-phase Multifunction AC/DC
power sources, up to 60,000VA AC
and 72,000W DC
OTHER EQUIPMENT
DPA 500N
1-phase Harmonics and Flicker
analyzer with built-in Flicker
impedance
www.emtest.com
© EM TEST > PAGE 4/5