Typical Cycle Time

1, 2

(ms) for Measurement Completion (Cont.)

Description

Typical Performance
(time/point in millisecond)

Number of Points

801 1601

Trigger Mode

Hardware

Sensitivity(dBm)

2


Start 2 GHz, Stop 18 GHz, 10 kHz IF bandwidth (with band crossings)

RF = MXG, N5183A opt. UNZ, Fast switching
LO = MXG, N5183A opt. UNZ, Fast switching

0.730

0.730

-110.5 dBm, 2 – 3 GHz
- 114.5 dBm, 3 –12.5 GHz
- 103 dBm, 12.5 – 18 GHz

RF = MXG, N5183A opt. UNZ, Fast switching

LO = N5264A opt. 108

3

0.730

0.730

-103.5 dBm, 2 – 3 GHz
- 110.5 dBm, 3 –12.5 GHz
- 101 dBm, 12.5 –18 GHz

RF = MXG, N5183A opt. UNZ, Fast switching
LO = PSG E8267D opt. 520, UNX

9.50 9.50

-110.25 dBm, 2 – 3 GHz
- 112.50 dBm, 3 –12.5 GHz
- 96.50 dBm, 12.5 – 18 GHz

RF = MXG, N5183A opt. UNZ, Fast switching
LO = 83623B

7.80 --

-108.5 dBm, 2 – 3 GHz
- 113.0 dBm, 3 –12.5 GHz
- 96.0 dBm, 12.5 –18 GHz

Start 2 GHz, Stop 18 GHz, 1 kHz IF bandwidth (with band crossings)

RF = MXG, N5183A opt. UNZ, Fast switching
LO = MXG, N5183A opt. UNZ, Fast switching

1.5

1.5

-120.5 dBm, 2 – 3 GHz
- 124.5 dBm, 3 –12.5 GHz
- 113 dBm, 12.5 – 18 GHz

RF = MXG, N5183A opt. UNZ, Fast switching

LO = N5264A opt. 108

3

1.5

1.5

-113.5 dBm, 2 – 3 GHz
- 120.5 dBm, 3 –12.5 GHz
- 111 dBm, 12.5 – 18 GHz

Option 118 Fast-CW mode (CW frequency)

Number of Points
per Second (#pt/Sec) External Trigger

C.W, 7.0 GHz, ≥1 MHz IF bandwidth

-- 400,000

C.W, 7.0 GHz, 600 KHz IF bandwidth

Up to 400,000

240,000

C.W, 7.0 GHz, 10 KHz IF bandwidth

Up to 8,200 7,000

C.W, 7.0 GHz, 1 KHz IF bandwidth

Up to 1,000 1,000