Do not use specimens which are explosive or inflammable, or which contain such

substances. To do so could be hazardous, as this may lead to fire or explosion.

Do not place corrosive materials in the chamber. If corrosive substances or

humidifying water is used, the life of the unit may be significantly shortened.

Do not place life forms or substances that exceed allowable heat generation.

Be sure to read the user’s manual before operation.

CAUTION

DANGER

SPECIFICATIONS

*1 The performance values are under the conditions of a +23℃ ambient temperature, relative humidity of 65%rh, rated voltage, and no specimen. Heat up time

and pull down time are those of single-unit operation of each chamber.

*2 The performance values are based on IEC60068-3-5:2001, JTM K07:2007.
*3 Temperature heat-up/pull-down time account for performance of each temperature chamber.
*4 Excluding protrusions.

*5 Compliance with CE Marking.

*6 At ambient temperature +23℃.

*7 At 1m from front of chamber, 1.2m from floor. (ISO 1996-1:2003 A-weighted sound pressure level) depending on environment

Model

TSE-11-A

System

2-zone transition by vertical transfer of specimen

Performance

*1

Te

s

t a

re

a

High temp. exposure range

+60 to +200℃ (+140 to +392℉)

Low temp. exposure range

−65 to 0℃ (−85 to +32℉)

Temperature fl uctuation

*2

±0.5℃ (±0.9℉)

Hot

chamber

Pre-heat upper limit

+200℃ (+392℉)

Temp. heat-up time

*3

Ambient temp. to +200℃ (+392℉) within 30 min.

Cl

o

d

chamber

Pre-cool lower limit

−80℃ (−112℉)

Temp. pull-down time

*3

Ambient temp. to −80℃ (−112℉) within 90 min.

T

e

m

p

. r

e

c

o

ve

ry

Recovery conditions

・ 2 zones
High temperature exposure: +150℃ (+302℉), 30 min.
Low temperature exposure: −65℃ (−85℉), 30 min.
・ Sensor position: Upstream
・ Specimen: Plastic molded ICs 2 kg

Temp. recovery time

within 5 min.

Construction

Test area

Shelf brackets on 2 levels of fi xed location

Heater

Stripped wire heater

Refrigeration

unit

System

Mechanical cascade refrigeration system

Compressor

Rotary 1.5 kW ×2

Refrigerant

R508A R404A

Condenser

Air-cooled condenser

Cooler

Plate fi n cooler, cold accumulator

Air circulator

Sirocco fan

Fittings

Specimen power supply control terminal, integrating hour meter without reset,
time signal (2), cable port 50 mm, (right side), casters with leveling feer (4), power cable

Test area load resistance

8 kg

Specimen basket load capacity

2kg per basket (equally distributed load)

Inside dimensions (W×H×D)

320Ч148Ч230mm (12.6Ч5.8Ч9 inch)

Test area capacity

10.9 L

Outside dimensions (W×H×D)

*4

680Ч1625Ч1050mm (26.8Ч64Ч41.3 inch)

Weight

approximately 390kg

Allowable ambient conditions

0 to +40℃ (+32 to +104℉)

Power supply
(Voltage fl uctuation: rating ±10%)

200V AC

3φ 3W 50/60Hz

220V AC

3φ 3W 60Hz

380V AC

3φ 4W 50Hz

400/415V AC
3φ 4W 50Hz

400V AC

*5

3φ 4W 50Hz

Maximum load current

26A

25A

17A

17A

17A

Exhaust heat quantity

*6

17,585kJ/h

Noise level

*7

60dB or less