Telecom surge, General data – Atec EM-Test-UCS500N5 User Manual
Page 7
DATA SHEET > UCS 500N5 > 20120518
TECHNICAL DETAILS
TELECOM SURGE
TSURGE MODULE, TSURGE5 (OPTIONAL)
Test voltage
160V - 5,000V ± 10%
Energy storage
capacitor
20uF
Polarity
Positive, negative, alternating
Counter
1 - 30,000 or endless, selctable
As per ITU and ETSI
recommendations
Front time
10us ± 30%
Pulse duration
700us ± 20%
As per FCC part 68, Pulse B
Front time
9us ± 30%
Pulse duration
720us ± 20%
Output current
4 - 125A (short-circuit)
Rise time
5us ± 30%
Pulse duration
320us ± 20%
As per IEC 61000-4-5
Rise time
6.5us ± 30%
Pulse duration
700us ± 20%
Output current
4A - 125A (short-circuit)
Rise time
4us ± 20%
Pulse duration
300us ± 20%
TRIGGER CIRCUIT
Trigger of events
Automatic, manual, external
Repetition rate
max. 0.5Hz (2s - 999s)
OUTPUTS
As per ITU
For 2-wire T1/T2 with 25ohm each
As per FCC part 68
For 2-wire T1/T2 with 25ohm each
As per IEC
61000-4-5
For 4-wire T1,T2,T3,T4 with 100ohm
each
For other requirements special
output configurations are available
OPTIONS
CNV 504S1
Coupling network for 4 telecom lines
as per IEC 61000-4-5
CNV 508S1
Coupling network for 8 telecom lines
as per IEC 61000-4-5
GENERAL DATA
INTERFACES
Serial interface
USB
Parallel interface
IEEE 488, addresses 1 - 30
Analog output
0 - 10VDC to control an external
transformer
CN interface
15pin SubD connector to control an
external coupling network
Fail inputs
DUT monitoring via Fail1 and Fail2
input (one each)
DIMENSIONS
Dimensions
19", 3HU,
19", 6HU, (with TSurge5 module)
Weight
approx. 25kg
MAINS
Supply voltage
115V/230VAC +10%/-15%
Power
approx. 75W
Frequency
50/60Hz
Fuses
2 x T 2AT (230V) or 2 x T 4AT (115V)
SAFETY
Safety standard
EN/IEC 61010
Security circuit
Control input (24VDC)
Warning lamp
Floating contact (max. 230V/6A)
ACCESSORIES INCLUDED
Mains supply
Plug depends on the country of use
DUT supply
Plug depends on the country of use
DUT adapter
Socket depends on the country of
use
Operation manual,
Calibration certificate,
iec.control remote control software
OPTIONS
CNI 503Ax
3-phase coupling/decoupling
networks as per IEC 61000-4-4 and
-4-5 up to 100A per phase
iec.control 1
Remote control and documentation
software, including standard test
routines and reporting capabilities.
www.emtest.com
© EM TEST > PAGE 7/8