beautypg.com

Atec Astro-Med-Dash-8XE User Manual

Page 9

background image

9.

IHV3 High voltage module


Connector

Guarded

banana

jacks

(red/black)

Isolation

250 VRMS or DC, Cat II. (iso-common to chassis
and other iso-commons)

Bandwidth

22 KHz (-3db) (350 through 40 V Atts)

20

KHz

(-3db)

(20

V

Att)

17 KHz (-3db) (10000 through 500 mV Atts)

12 KHz (-3db) (100 through 50 mV Atts)

Input

Single-ended,

DC

coupled

Zero Suppression

Yes. digital

Measurement Ranges

+/- 350 V

+/-

200

V

+/-

100

V

+/- 50 V

+/- 40 V

+/- 20 V

+/-

10000

mV

+/-

5000

mV

+/-

1000

mV

+/-

500

mV

+/-

100

mV

+/- 50 mV

Max Rated Input

+/- 250 Vrms or DC

Max Transient Input

+/- 800 V (not to exceed 250 Vrms)

A/D

16

bit

SAR

Anti-Aliasing Filter

4 pole Bessel

Accuracy (25°C)

+/- 0.15% of Attenuator

Cold Start Drift

Less than 0.5% of attenuator

Intrinsic Noise (pk-pk)

< 0.2 % of Attenuator (Volt Attenuators)

< 0.2 % of Attenuator + 2 mV (mV Attenuators)

Min Input Impedance

1 M ohm

IMR at 60 Hz (Volt Attens.) > 50 dB
IMR at 60 Hz (mVolt Attens) > 60 dB
Channels Per Module

1

Frequency Counter

Yes. Software selectable.

Module Part Number

32750-130



Specifications subject to change without notice