34460A/34461A

O P T I O N S & A C C E S S O R I E S

Accessories

Accessories included

34460A:

Power cord
Calibration certifi cate

34461A:

34138A test lead set with probes, fi ne tip probes, SMT grabbers

and mini grabber attachments

Power cord

Documentation CD

IO Libraries CD

USB cable

Calibration certifi cate

Accessories available

11059A

Kelvin probe set

11060A

Surface-mount device probe

11062A

Kelvin clip set

34131A

Transit case

34133A

Precision electronic test leads

34134A

DC-coupled current probe

34136A

High-voltage probe

34138A

Test lead set

34162A

Accessory pouch

34171B

Input terminal block

34172B

Calibration short

34308A

Thermistor kit

34330A

30-A current shunt

E2308A

Thermistor temperature probe

Y1133A

Low-thermal external digital multimeter scanning kit

Options

34460A Digital multimeter, 6½ digit, basic Truevolt DMM

LAN

Rear panel LAN/LXI Web interface, external triggering for 34460A

SEC

Enable NISPOM and fi le security for Truevolt Series DMMs

Z54

Certifi cate of calibration – ANSI/NCSL Z540.3-2006, printed

GPB

GPIB user-installable interface module for Truevolt Series DMMs

ACC

Accessory kit for 34460A – documentation CDs, test leads, USB cable

34461A Digital multimeter, 6½ digit, 34401A replacement, Truevolt DMM

SEC

Enable NISPOM and fi le security for Truevolt Series DMMs

Z54

Certifi cate of calibration – ANSI/NCSL Z540.3-2006, printed

GPB

GPIB user-installable interface module for Truevolt Series DMMs

Standalone product numbers

Ordered as standalone to be installed by the distributor or customer

3446LANU

Upgrade:
Rear panel LAN/LXI Web interface, external triggering for 34460A

3446SECU

Upgrade:
Enable NISPOM and fi le security for Truevolt Series DMMs

3446GPBU

Upgrade:
GPIB user-installable interface module for Truevolt Series DMMs

3446ACCU

Accessory kit for 34460A:
Documentation CDs, test leads, USB cable

Rack mount kits

34190A

Rackmount kit:
Use for mounting one 2U instrument by itself, without another instrument
laterally next to it. Includes one rack fl ange and one combination
rack fl ange-fi ller panel.

34191A

2U dual fl ange kit:
Use for mounting two 2U instruments side-by-side.
Includes two standard rack fl anges.
Note: Mounting two instruments side-by-side will require the
34194A dual-lock link kit and a shelf for the instruments to sit on.

34194A

Dual lock link kit:
For side-by-side combinations of instruments and includes links
for instruments of different depths.

Defi nitions

Specifi cation (spec)

The warranted performance of a calibrated instrument that has been stored for a
minimum of 2 hours within the operating temperature range of 0 – 55 °C and after a
60-minute warm up period. All specifi cations include measurement uncertainty and
were created in compliance with ISO-17025 methods. Data published in this document
are specifi cations (spec) only where specifi cally indicated.

Typical (typ)

The characteristic performance, which 80% or more of manufactured instruments will
meet. This data is not warranted, does not include measurement uncertainty, and is
valid only at room temperature (approximately 23 °C).

Nominal (nom)

The mean or average characteristic performance, or the value of an attribute that is
determined by design such as a connector type, physical dimension, or operating speed.
This data is not warranted and is measured at room temperature (approximately 23 °C).

Measured (meas)

An attribute measured during development for purposes of communicating the expected
performance. This data is not warranted and is measured at room temperature (ap-
proximately 23 °C).

T

CAL

The temperature at which the instrument was calibrated.

Standard 3-Year Warranty