beautypg.com

Cable and antenna analyzer – Atec Anritsu-S331E-S332E-S361E-S362E User Manual

Page 2

background image

Page 2 of 16

Site Master™ S331E, S332E, S361E, S362E Specifications

Cable and Antenna Analyzer

Measurements

Measurements

VSWR
Return Loss
Cable Loss
Distance-to-Fault (DTF) Return Loss
Distance-to-Fault (DTF) VSWR
1-Port Phase
Smith Chart

Setup Parameters

Measurement Display

Single/Dual Measurement Display with independent markers

Frequency

Start/Stop, Signal Standard, Start Cal

DTF

Start/Stop, DTF Aid, Units (m/ft), Cable Loss, Propagation Velocity, Cable, Windowing

Windowing

Rectangular, Normal Side Lobe, Low Side Lobe, Minimum Side Lobe

Amplitude

Top, Bottom, Auto Scale, Full Scale

Sweep

Run/Hold, Single/Continuous, RF Immunity (High/Low), Data Points, Averaging/Smoothing,

Output Power (High/Low)

Data Points

137, 275, 551, 1102, 2204

Markers

Markers 1-6 (On/Off), Delta Makers 1-6 (On/Off), Marker to Peak/Valley, Marker Table

Traces

Recall, Copy to Display Memory, No Trace Math, Trace ± Memory, Trace Overlay

Limit Line

On/Off, Single Limit, Multi-segment (41), Limit Alarm, Clear

Calibration

Start Cal, Cal Type (Standard/FlexCal™)

Save/Recall

Setups, Measurements (.vna, .dat), Screen Shots Jpeg (save only)

Application Options

Bias-Tee (On/Off), Impedance (50 Ω, 75 Ω, Other)

Frequency

Frequency Range

2 MHz to 4 GHz (S331E, S332E), 2 MHz to 6 GHz (S361E, S362E)

Frequency Accuracy

≤ ± 2.5 ppm @ 25 °C

Frequency Resolution

1 kHz, (RF immunity low)

100 kHz, (RF immunity high)

Output Power

High

0 dBm, typical

Low

–30 dBm, typical

Interference Immunity

On-Channel

+17 dBm @ > 1.0 MHz from carrier frequency

On-Frequency

0 dBm within ± 10 kHz of the carrier frequency

Measurement Speed

Return Loss

≤ 1.00 msec/data point, RF immunity low, typical

Distance-to-Fault

≤ 1.25 msec/data point, RF immunity low, typical

Return Loss

Measurement Range

0 to 60 dB

Resolution

0.01 dB

VSWR

Measurement Range

1 to 65

Resolution

0.01

Cable Loss

Measurement Range

0 to 30 dB

Resolution

0.01 dB

Distance-to-Fault

Vertical Range Return Loss

0 to 60 dB

Vertical Range VSWR

1 to 65

Fault Resolution (meters)

(1.5 x 10

8

x vp)/∆F (vp = velocity propagation constant, ∆F is F2-F1 in Hz)

Horizontal Range (meters)

0 to (Data Points-1) x Fault Resolution, to a maximum of 1500 meters (4921 ft)

1-Port Phase

Measurement Range

–180° to +180°

Resolution

0.01°

Smith Chart

Resolution

0.01