Ordering information (continued), Power monitor - detectors, Miscellaneous accessories – Atec Anritsu-S412D User Manual
Page 15: High accuracy power meter accessories, Manuals, Training course, Detector extension cables
15
Ordering Information (Continued)
Miscellaneous Accessories
2000-1410
Magnet Mount GPS Antenna with 15 ft. (4.57 m) cable
551-1691-R
USB to RS-232 adapter cable
67135
Backpack, 25 lb. max weight limit
65717
Soft Carrying Case
760-243-R
Transit Case
633-27
Rechargeable Battery, NiMH
2000-1029
Battery Charger, NiMH, w/ Universal Power Supply
40-168-R
AC/DC Adapter
806-141
Automotive Cigarette Lighter/12 Volt DC Adapter
800-441
Serial Interface Cable
2300-498
Master Software Tools CDROM
High Accuracy Power Meter Accessories
PSN50
High Accuracy Power Sensor, 50 MHz to 6 GHz
40-168-R
AC-DC Adapter
800-441
Serial Interface Cable
3-1010-122
Attenuator, 20 dB, 5 Watt, DC to 12.4 GHz, N(m)-N(f)
3-1010-123
Attenuator (Bi-directional), 30 dB, 50 Watt,
DC to 8.5 GHz, N(m)-N(f)
3-1010-124
Attenuator (Uni-directional), 40 dB, 100 Watt,
DC to 8.5 GHz, N(m)-N(f)
1010-127-R
Attenuator, 30 dB, 150W, DC to 3 GHz, N(m)-N(f)
1010-128-R
Attenuator, 40 dB, 150W, DC to 3 GHz, N(m)-N(f)
65701
3 GHz Offset Cal Kit consisting of one each:
3-1010-119, 10 dB Attenuator, DC to 6 GHz, 2W
3-806-151, 4 GHz Cable, 18” (46 cm)
Manuals
10580-00260
LMR Master User Guide (for Model S412D)
10580-00261
LMR Master Programming Manual (for Model S412D)
Training Course
10580-00263
Interference Analysis for Land Mobile Radio
Power Monitor - Detectors
The 5400 and 560 Series Detectors use zero-biased Schottky diodes. Measurement range is –55 dBm to +16 dBm using
single cycle per sweep AC detection, auto-zeroing with DC detection during the frequency sweep. Extender cables of over
3000 feet (914.4 meters) can be used with the S412D LMR Master.
Model
Frequency Range
Impedance
Return Loss
Input Connector
Frequency Response
5400-71N50
0.001 to 3 GHz
50 Ω
26 dB
N(m)
±0.2 dB, <1 GHz
±0.3 dB, <3 GHz
5400-71N75
0.001 to 3 GHz
75 Ω
26 dB, <2 GHz
20 dB, <3 GHz
N(m)
±0.2 dB, <1 GHz
±0.5 dB, <3 GHz
560-7N50B
0.01 to 20 GHz
50 Ω
15 dB, <0.04 GHz
22 dB, <8 GHz
17 dB, <18 GHz
14 dB, <20 GHz
N(m)
±0.5 dB, <18 GHz
±1.25 dB, <20 GHz
560-7S50B
0.01 to 20 GHz
50 Ω
15 dB, <0.04 GHz
22 dB, <8 GHz
17 dB, <18 GHz
14 dB, <20 GHz
WSMA(m)
±0.5 dB, <18 GHz
±1.25 dB, <20 GHz
560-7K50
0.01 to 40 GHz
50 Ω
12 dB, <0.04 GHz
22 dB, <8 GHz
17 dB, <18 GHz
15 dB, <26.5 GHz
14 dB, <32 GHz
13 dB, <40 GHz
K(m)
±0.5 dB, <18 GHz
±1.25 dB, <26.5 GHz
±2.2 dB, <32 GHz
±2.5 dB, <40 GHz
560-7VA50
0.01 to 50 GHz
50 Ω
12 dB, <0.04 GHz
19 dB, <20 GHz
15 dB, <40 GHz
10 dB, <50 GHz
V(m)
±0.8 dB, <20 GHz
±2.5 dB, <40 GHz
±3.0 dB, <50 GHz
Detector Extension Cables
800-109
7.6 m (25 ft.)
800-111
30.5 m (100 ft.)