beautypg.com

Associated Equipment 12-1015 Quick Guide User Manual

Page 6

background image

6

26. Press

key to continue and the display

will show as follows:














27. Switch the ignition key to ON and start

cranking the engine until it starts. Immediately
after that press key and the results will
show as follows

:














28. If the voltage drop is too great during the

cranking, the tested results will display as
follows and will prompt you to check the
starter system.







29. During cranking when it detects that there is

no drop in voltage, it will display the following
screen:













30. To exit the program, pressing the

key at any moment will exit and return back
to the main menu screen.

Alternator Test

No load testing at 3000 RPM:

31. With engine OFF, place the vehicle

transmission in NEUTRAL for Manual and
PARK for Automatic and apply the parking
brake.

32. Pressing key once will scroll down to the

“Alternator Test”





















Starter Test


Battery: 12.45V


Crank engine now
until it starts. Then
press [Enter].

Result: OK

Min. Volts: 10.56V
Volt Drop: Normal

Press [Exit] to main
menu.

Result: High Drop

Min. Volts: 8.56V
Volt Drop: High

Check starter relay,
battery terminals or
battery has aged.
Press [Exit] to main
menu.

Result: Not detected

No change in volt drop.
Check clamping at
battery side and test
again.


Press [Exit] to main
menu.

Select Test

Battery Test
Grounding Test
Starter Test

Alternator Test

Then press [Enter]