beautypg.com

5 configuring the input/output voltage (continued), Output terminal block, Step 3: reconfigure the output terminal block 1 – Alpha Technologies CFR 5000, CFR 5000RM User Manual

Page 78: Voltage reconfiguration finished, Transformer this way, Rear panel this way

background image

5 Maintenance

72

Alpha Technologies

5.5 Configuring the Input/Output Voltage (Continued)

Output
Terminal

Block

Step 3: Reconfigure the Output Terminal Block

1

Find the output terminal block, which is mounted on the bottom panel between the

transformer and the rear panel.

1

2

3

4

1

2

3

4

1

2

3

4

120 VAC Output

Transformer This Way

208 VAC Output

240 VAC Output

120

N

120

N

120

N

208

240

To Output

Receptacles

To Output

Receptacles

Rear Panel This Way

2

If needed, configure the output terminal block to the output voltage you are using as

shown below.

3

Reattach all of the unit’s panels.

4

Turn on the unit (Section 3.1). Before turning on the loads, measure the output

voltage to make sure this procedure has been done correctly.

Voltage Reconfiguration Finished