Status LED on the Secvest IP

Green LED (“Power” LED) for monitoring the power supply

• Permanently lit: power supply is OK
• Flashing with 1 Hz: mains power supply failure; is only indicated if

a backup battery is in use.

Red LED (“Trouble” LED) for indicating faults

• Off: no faults
• Flashing with 1 Hz: supervision fault (detector or device is indicated

by the channel LED flashing with 1 Hz. If only this LED flashes, this
indicates that the control panel itself has been tampered with).

• Permanently lit: indicates jamming.

Blue LEDs (“Channel” LEDs) for detector status display

• Off: detector OK (closed)
• Permanently lit: detector is open, or has triggered (open),

operating units are lit briefly signalising that a radio signal has
been sent.

• Flashing with 5 Hz: low battery
• Flashing with 1 Hz: tampering with detector or device

Bottom blue LED lights up: indicates that this refers to the second
caption level. (i.e. channels 8-14)