Programming keys
Tamper switch
A cover tamper switch (B) and a wall tamper switch protect the control panel
from unauthorised opening and removal from the wall.
CON1
CON1 jumper connection “FIT DISABLE TAMP” (C)
If you set the jumper on both contacts, you deactivate the wall
removal contact.
(This may be helpful during programming.)
CON2
CON2 jumper (D) must be in the “-” position (factory setting).
DIP switch SW6
Switch positions 4/5/7/8 must remain in the factory settings to guarantee
functioning.
A
B
C
D
E
Switch
Options
Factory settings
“OFF” position
“ON” position
1
Supervision
ON
Off
On
2
Supervision time
ON
Long 3 h
Short 20 min
3
Jamming detection
ON
Off
On
4
OFF
5
ON
6
LED mode
OFF
Display on
Display off
7
OFF
8
Acoustic signalling
ON
Off
On
SELECT
ESC/DEL
SW4
SET
CON2
VSEL