ABUS SG1660 Optic_acoustic combination signal transmitter User Manual

Page 8

background image


8

Installation

1. Use the back of the flash and sounder case as a template for marking

the drill holes (2). Drill the holes for the fixing screws.

2. Pull the connector cable through the opening provided.
3. Fix the rear of the casing and the removal contact (7) to the wall.
4. Connect the cables to the terminal block (8) as described .
5. Replace the protective cover (9) and the casing cover (1) and tighten

the fixing screws.

IMPORTANT: Make sure you connect the cables to the
right polarity, otherwise the flashlight may be irreparably
damaged.

Connections

Use only shielded and grounded cables.

Connect the flash and sounder cables to the corresponding control or
switching outputs of your alarm system. Check the total power
consumption. You can also incorporate the cover contact into the tamper
line of your alarm system.


Technical data

Voltage supply

10–15 V DC

Max. power consumption (without
flash)

340mA

Max. power consumption (with
flash)

750mA

Acoustic alarm

110dB @ 1m

Protection type

IP34

Operating temperature

-25 to +55°C

Dimensions (WxHxD)

190 x 310 x 120 mm

Weight with flash / without flash

1,850g / 1,700g


The manufacturer reserves the right to make technical modifications
without prior notice.