Elmo Rietschle L-BV7 User Manual
Page 41
![background image](/manuals/316316/41/background.png)
© Gardner Denver Deutschland GmbH
41 / 64
610.48060.40.000
Servicing
11.3 Spare
parts
11.3.1 Ordering nash_elmo spare parts
When ordering nash_elmo spare parts, always
indicate the following:
Type designation ("2BV...", "2BH..." or
"2BL..."), complete with all additions
(as per rating plate)
Serial number ("No E"), 13-digit
(as per rating plate)
Part item number, 4-digit
(as per parts list for exploded view,
Chapter 14, "Exploded View with Parts
List", Pg. 50)
Example of an order:
2BV7071-1AH08S(-Z) =
Type
designation
No E F2 7 45688 70 010
= Serial number
047
= Part item #
Impeller =
Part
designation
All parts of the parts list for the exploded view
are available from the manufacturer under the
corresponding item number.
See Chapter 14, "Exploded View with Parts
List", Pg. 50.
In case of inquiries, the serial number (No E)
of the pump-motor unit must be specified in
accordance with the rating plate.
11.3.2 Ordering standardized parts
Commercially available standardized parts can
be purchased on the open market.
When doing so, observe the information in the
parts list exactly, especially the design,
dimensions, property class etc.
11.4 Service/After-sales
service
Our Service is available for work (in particular
the installation of spare parts, as well as
maintenance and repair work), not described in
these operating instructions (see front page of
these operating instructions).
Observe the following when returning pump-
motor unit:
Before
shipping:
–
Drain the pump-motor unit so that it is
residue-free,
as described in Chapter 10.1, "Draining",
Pg. 34.
–
Clean the unit on the inside and outside,
as described in Chapter 11.1,
"Maintenance", Pg. 36.
The pump-motor unit must be delivered
complete, i.e. not dismantled.
Only the original packing should be used for
shipment.
A declaration of clearance must be included
with the shipment,
as described in Chapter 11.5,
"Decontamination and Declaration of
Clearance", Pg. 42.
The original rating plate of the pump-motor
unit must be properly mounted, intact and
legible.
All warranty claims are voided for pump-
motor units delivered for a damage
expertise without the original rating plate or
with a destroyed original rating plate.