Elmo Rietschle L-BV7 User Manual
Page 16

610.48060.40.000
16 / 64
© Gardner Denver Deutschland GmbH
Technical Data
Weight
Type Weight
[kg]
[lbs]
2BV7 060-1A.0.
approx. 16
approx. 35.3
2BV7 060-2A.0.
approx. 17
approx. 37.5
2BV7 060-3A.0.
approx. 18
approx. 39.7
2BV7 061-1A.0.
approx. 22
approx. 48.5
2BV7 070-1A.0.
approx. 31
approx. 68.3
2BV7 070-2A.0.
approx. 35
approx. 77.2
2BV7 070-3A.0.
approx. 48
approx. 106
2BV7 071-1A.0.
approx. 39
approx. 86
2BV7 071-2A.0.
approx. 50
approx. 110
2BV7 071-3A.0.
approx. 56
approx. 123
Minimum distances for heat dissipation
Minimum distance from
fan guard to adjacent surface
Type
[mm] [inches]
2BV7 060
34
1.34
2BV7 061
34
1.34
2BV7 070
53
2.09
2BV7 071
53
2.09
Noise level
Measuring-surface sound pressure level as per
EN ISO 3744, measured at distance of 1 m
[3.28 ft] with medium throttling (100 mbar abs.
[1.45 psia]) and connected lines, tolerance 3
dB (A).
1-m measuring-surface sound
pressure level L [dB (A)]
Type
at 50 Hz:
at 60 Hz:
2BV7 060
70
2BV7 061
70
2BV7 070
72
2BV7 071
70
76
Limit speeds for supply by converter
Type n
[rpm]
2BV706 4,800
2BV707 4,000
4.2 Electrical
data
See drive motor rating plate.
4.3 Operating
conditions
Temperatures
max. +80 °C [max. +176 °F]
Temperature
of pumped
gases/vapors:
At higher fluid temperatures,
measures must be taken on
the system to prevent burns,
e.g. mount separating safety
device (cover).
max. +80 °C [max. +176 °F]
min. +5 °C
[min. +41 °F]
Operating-
liquid
temperature:
Nominal
value:
+15 °C
[+59 °F]
max. +40 °C [+104 °F]
Ambient
temperature:
min. +5 °C
[+41 °F]
Pressures
Min. inlet
pressure:
Dependent on the operating
liquid temperature
(see Fig. 2, Pg. 17)
When this temperature is
dropped below, the hose of
the liquid separator
(accessory) must be
connected to the connection
for cavitation protection
(Fig. 7, Pg. 25, Item 4).
Max.
discharge
pressure
during
vacuum-pump
operation:
1.1 bar abs. [16.0 psia]
8 bar abs.
[116 psia]
Max.
permissible
pressure in
pump-motor
unit:
If higher pressures can occur
in the system, then
corresponding protective
devices must be provided.
Max. discharge pressure p
2 max
during
compressor operation (at inlet pressure p
1
=
1 bar abs. [14.5 psia]):
p
2 max
[bar abs.]
[psia]
Type
at
50 Hz:
at
60 Hz:
at
50 Hz:
at
60 Hz:
2BV7
060 2 2 29.0
29.0
2BV7
061 2 2 29.0
29.0
2BV7 070
3
2.5
43.5
36.3
2BV7
071 3.5 2.5 50.8 36.3