Description of Vacuum Pump/Compressor
5.3 Operating
modes
The pump-motor unit can function in several
different operating modes.
These differ in how the pump-motor unit is
supplied with operating liquid:
Self-priming
operation
Operation with operating-liquid feed:
–
Non-automatic operation
–
Automatic operation
5.3.1 Self-priming
operation
In this operating mode the pump-motor unit
automatically sucks in the operating liquid.
The operating-liquid flow rate is automatically
adjusted.
See Fig. 8, Pg. 30.
5.3.2 Operation with operating-liquid feed
In this operating mode the pump-motor unit
DOES NOT automatically suck in the operating
liquid.
A certain volume flow ("nominal operating-
liquid flow rate") or pre-pressure must be set
for the operating liquid.
Here the following additional distinctions are
made:
Non-automatic operation
In this case the operating liquid feed is
switched on and off manually with a stop valve.
See Fig. 11, Pg. 32.
Automatic operation
In this case the operating liquid feed is
switched on and off by a solenoid valve. The
solenoid valve is dependent on the motor
operating mode:
Motor/pump-motor unit switched on:
Valve open.
Motor/pump-motor unit switched off:
Valve closed.
See Fig. 12, Pg. 32.
NOTICE
The following is dependent on
the operating mode:
when and how the pump-
motor unit must be filled with
operating liquid the first time,
how the pump-motor unit is
put into operation.
The specifications for this are
contained in Chapter 7,
"Installation", Pg. 22ff., and
Chapter 8, "Commissioning",
Pg. 28ff.