Step 5: Insert straightened Swivel Insert/Measurement
Cylinder Assembly into valve, orient arrow on
wrench flat to point downstream

Step 6: Loosen Thumb Set Screw. Remove Locking Collar
from tool. Remove tool and re-insert opposite end into
Swivel Assembly. Engage the tool and push firmly to orient
Measurement Cylinder 90˚ into flow path

Verify score mark is

flush with flat face

of straight thread

to ensure full

engagement

Step 7: Remove tool from Threaded Swivel Insert

Step 8: Insert tip of e-FlowMeter Sensor/Head Assembly

into Threaded Swivel Insert

Step 9: Line-Up Centering Groove on straight threads

with Centering Pin; push to seat o-ring

Centering

Groove

Centering

Pin

Knurled

Lock

Step 10: HAND TIGHTEN Knurled Lock onto straight

threads. Tighten Allen Set Screw with M3 Allen
Wrench to lock Sensor Head Assembly.

Proceed in accordance with Wiring Diagram

top view

inside view

flow

Allen Set

Screw