beautypg.com

Consumables, Other s – Pump Solutions Group Neptune Solenoid-driven Diaphragm Metering Pump ARPZ-31_61_12 User Manual

Page 52

background image

51

Other

s

Part

Recommended

replacement timeframe

31/61/12

2
1

Relief valve

Quantity per pump

Valve seat assembly

Every 10,000 hours

Diaphragm assembly (diaphragm, protective diaphragm, spacer)

Every 10,000 hours

1

Every 10,000 hours*

Air-release nozzle assembly

1

Every 10,000 hours

Part

Quantity per pump

Recommended

replacement timeframe

31/61/12

2
1

Relief valve

1

Valve seat assembly

Every 10,000 hours

Diaphragm assembly (diaphragm, protective diaphragm, spacer)

Every 10,000 hours
Every 10,000 hours*

Air-release nozzle assembly

1

Every 10,000 hours

• Failure to replace the consumables may cause discharge (or injection) trouble and/or malfunctions.
• The replacement timeframes of the consumables have been determined under the prescribed conditions (clean

water, room temperature) prevailing at TACMINA’s test facilities.

• Since these timeframes will differ under the individual conditions prevailing on-site, use them as a general guide, and

replace the consumables at an earlier rather than later date.

Consumables

!

CAUTION

• The durability of a hose/tube differs significantly depending on the chemicals with which it is used, on

the temperatures and pressures and on the presence of ultraviolet rays. Inspect the hoses/tubes, and
replace them if they have deteriorated.

NOTE

• TACMINA will continue to supply consumables for its pumps for a period of eight (8) years after the

manufacture of the pumps has been discontinued.

• “Parts kits” consisting of a complete set of consumables are available (except for some models).

For details on how to replace the consumables, refer to “Replacing the diaphragm”, “Replacing the valve seats and
check balls” and” Replacing the relief valve” (on page 30 to 35).

Model for injection of general chemicals: PZ-31/61/12-VEC/VFC/FEC/FFC/FTC

PZ-31/61/12-VEC/VFC

* The timeframe applies when the relief-valve function has not been activated at all. If it has been activated, replace it regardless of how long it has been in use.

PZ-31/61/12-FEC/FFC/FTC

* The timeframe applies when the relief-valve function has not been activated at all. If it has been activated, replace it regardless of how long it has been in use.

Part

Quantity per pump

Recommended

replacement timeframe

31

2

1

Relief valve

1

Valve seat assembly

Every 10,000 hours

Diaphragm assembly (diaphragm, protective diaphragm, spacer)

Every 10,000 hours

Every 10,000 hours*

Air-release nozzle assembly

1

Every 10,000 hours

Model for injection of boiler chemicals: PZ-31-FEC (PP)

* The timeframe applies when the relief-valve function has not been activated at all. If it has been activated, replace it regardless of how long it has been in use.

51-54_PZ総合取説_E.indd 51

51-54_PZ総合取説_E.indd 51

2008/01/23 11:08:09

2008/01/23 11:08:09

This manual is related to the following products: